FORCE10-TRAP-EVENT-MIB :: f10ChassisTrapEventId

MIB Reference — IPNetwork Monitor · Updated October 05, 2026

All MIBs › FORCE10-TRAP-EVENT-MIB › f10ChassisTrapEventId

f10ChassisTrapEventId

Module: FORCE10-TRAP-EVENT-MIB

OID (symbolic): FORCE10-TRAP-EVENT-MIB::f10ChassisTrapEventId

OID (numeric): 1.3.6.1.4.1.6027.3.6.1.1.1

Node type: OBJECT-TYPE

Type: DateAndTime

Access: read-only

Description: The f10ChassisTrapEventId used the timestamp as the ID to uniquely identify the current trap event table.

Each time a NMS connect to F10 Chassis, it should verify its f10ChassisTrapEventId. If the ID is different, it should refresh its history and active tables.

But, if the f10ChassisTrapEventId is the same, then it should query the f10LastTrapEventSeqId and update its history and active tables from its own f10LastTrapEventSeqId to the chassis f10LastTrapEventSeqId.

What is f10ChassisTrapEventId?

This DateAndTime value is a timestamp used as a unique ID for the chassis's current trap-event table generation. Per the MIB, a management station compares this ID on each reconnect to detect whether the chassis has reset its trap tables, in which case it must fully refresh its history and active trap data instead of incrementally syncing from f10LastTrapEventSeqId. For example, if a reconnecting NMS finds a new f10ChassisTrapEventId timestamp, it knows the chassis rebooted and its cached trap history is stale.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.6027.3.6.1.1.1
snmpwalk -v2c -c public <target> FORCE10-TRAP-EVENT-MIB::f10ChassisTrapEventId

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.6027.3.6.1.1.1.1
snmpget -v2c -c public <target> FORCE10-TRAP-EVENT-MIB::f10ChassisTrapEventId.1

SNMPv3 example:

snmpget -v3 -l authPriv -u snmpv3-user -a SHA -A "AuthPassword1" -x AES -X "PrivPassword1" <target> f10ChassisTrapEventId.1

Start monitoring Dell Force10 (Dell Networking OS/FTOS) chassis switch/router (trap/alarm event log) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the FORCE10-TRAP-EVENT-MIB::f10ChassisTrapEventId OID value, configure state conditions and alerts, and monitor any Dell Force10 (Dell Networking OS/FTOS) chassis switch/router (trap/alarm event log) from a single console.

OID Breakdown

Upper-level ancestors (11 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.6027dellNetDELL-NETWORKING-SMI
1.3.6.1.4.1.6027.3dellNetMgmtDELL-NETWORKING-SMI
1.3.6.1.4.1.6027.3.6dellNetTrapEventMibDELL-NETWORKING-TRAP-EVENT-MIB
1.3.6.1.4.1.6027.3.6.1dellNetTrapEventObjectsDELL-NETWORKING-TRAP-EVENT-MIB
1.3.6.1.4.1.6027.3.6.1.1dellNetHistoryTrapEventDELL-NETWORKING-TRAP-EVENT-MIB
Numeric OIDNameModule
1.3.6.1.4.1.6027.3.6.1.1.1f10ChassisTrapEventIdFORCE10-TRAP-EVENT-MIB