All MIBs › FORCE10-COPY-CONFIG-MIB › copySrcFileLocation
copySrcFileLocation
Module: FORCE10-COPY-CONFIG-MIB
OID (symbolic): FORCE10-COPY-CONFIG-MIB::copySrcFileLocation
OID (numeric): 1.3.6.1.4.1.6027.3.5.1.1.1.1.3
Node type: OBJECT-TYPE
Type: F10ConfigFileLocation
Access: read-write
Description: Specifies the location of source file.
If the copySrcFileType has the value of ftosFile(1), it is expected that the copySrcFileType and copySrcFileName must also be spcified. The three objects together will uniquely identify the source file.
If the copySrcFileLocation has the value of ftp(4) or scp(5), it is expected the login information liked copyServerAddress, copyUserName, and copyUserPassword also be spcified.
What is copySrcFileLocation?
copySrcFileLocation specifies where the source file for a Force10 copy operation lives, such as flash, ftp, or scp, per its description. An admin must set this together with copySrcFileType and copySrcFileName when the type is ftosFile, and must also populate the server and login objects, copyServerInetAddress, copyUserName, copyUserPassword, when the location is ftp(4) or scp(5). For example, setting copySrcFileLocation to scp(5) means the admin also needs to fill in copyServerInetAddress and login credentials so the switch knows which remote server to pull the file from.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.6027.3.5.1.1.1.1.3 snmpwalk -v2c -c public <target> FORCE10-COPY-CONFIG-MIB::copySrcFileLocation
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.6027.3.5.1.1.1.1.3.1 snmpget -v2c -c public <target> FORCE10-COPY-CONFIG-MIB::copySrcFileLocation.1
Set instance 1 (SNMPv2c):
snmpset -v2c -c private <target> 1.3.6.1.4.1.6027.3.5.1.1.1.1.3.1 s <value>
Start monitoring Dell Force10 (Dell Networking OS/FTOS) switch/router (config/image file copy) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the FORCE10-COPY-CONFIG-MIB::copySrcFileLocation OID value, configure state conditions and alerts, and monitor any Dell Force10 (Dell Networking OS/FTOS) switch/router (config/image file copy) from a single console.
OID Breakdown
Upper-level ancestors (13 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.6027 | dellNet | DELL-NETWORKING-SMI |
| 1.3.6.1.4.1.6027.3 | dellNetMgmt | DELL-NETWORKING-SMI |
| 1.3.6.1.4.1.6027.3.5 | dellNetCopyConfigMib | DELL-NETWORKING-COPY-CONFIG-MIB |
| 1.3.6.1.4.1.6027.3.5.1 | dellNetCopyConfigObjects | DELL-NETWORKING-COPY-CONFIG-MIB |
| 1.3.6.1.4.1.6027.3.5.1.1 | dellNetCopyConfig | DELL-NETWORKING-COPY-CONFIG-MIB |
| 1.3.6.1.4.1.6027.3.5.1.1.1 | dellNetCopyTable | DELL-NETWORKING-COPY-CONFIG-MIB |
| 1.3.6.1.4.1.6027.3.5.1.1.1.1 | dellNetCopyEntry | DELL-NETWORKING-COPY-CONFIG-MIB |
| Numeric OID | Name | Module |
|---|---|---|