All MIBs › F3-SYNC-MIB › f3TimeClockSelectionMode
f3TimeClockSelectionMode
Module: F3-SYNC-MIB
OID (symbolic): F3-SYNC-MIB::f3TimeClockSelectionMode
OID (numeric): 1.3.6.1.4.1.2544.1.12.12.1.3.1.9
Node type: OBJECT-TYPE
Type: SyncSelectionMode
Access: read-write
Description: !! Currently Only Priority Mode is supported !! This object represents the Time Clock entity's selection mode. If this mode is configured as ql-mode, the selection of which reference should be used shall be based upon the reference's Quality Level. The highest received Quality Level shall be the selected reference. The priority shall only be used to distinguish between references with the same received QL. When multiple references have the same QL and same priority, the behavior of selection process within the group is non-revertive. If this mode is configued as priority-mode, the selection of which reference should be used shall be based upon the reference's priority (i.e. QL is disabled). When multiple references have the same priority, the behavior of selection process within the group is non-revertive.
What is f3TimeClockSelectionMode?
Controls how the Time Clock selects among its candidate references; the MIB notes that only priority-mode is currently supported in practice, where the configured priority value - not Quality Level - decides which reference is used.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.2544.1.12.12.1.3.1.9 snmpwalk -v2c -c public <target> F3-SYNC-MIB::f3TimeClockSelectionMode
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.2544.1.12.12.1.3.1.9.1 snmpget -v2c -c public <target> F3-SYNC-MIB::f3TimeClockSelectionMode.1
Set instance 1 (SNMPv2c):
snmpset -v2c -c private <target> 1.3.6.1.4.1.2544.1.12.12.1.3.1.9.1 s <value>
Start monitoring ADVA Optical Networking FSP150CM/CC (F3 platform) carrier Ethernet device (SyncE/timing synchronization) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the F3-SYNC-MIB::f3TimeClockSelectionMode OID value, configure state conditions and alerts, and monitor any ADVA Optical Networking FSP150CM/CC (F3 platform) carrier Ethernet device (SyncE/timing synchronization) from a single console.
OID Breakdown
Upper-level ancestors (9 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.2544 | advaMIB | ADVA-MIB |
| 1.3.6.1.4.1.2544.1 | products | ADVA-MIB |
| 1.3.6.1.4.1.2544.1.12 | fsp150cm | ADVA-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.2544.1.12.12 | f3SyncMIB | F3-SYNC-MIB |
| 1.3.6.1.4.1.2544.1.12.12.1 | f3SyncObjects | F3-SYNC-MIB |
| 1.3.6.1.4.1.2544.1.12.12.1.3 | f3TimeClockTable | F3-SYNC-MIB |
| 1.3.6.1.4.1.2544.1.12.12.1.3.1 | f3TimeClockEntry | F3-SYNC-MIB |
| 1.3.6.1.4.1.2544.1.12.12.1.3.1.9 | f3TimeClockSelectionMode | F3-SYNC-MIB |