All MIBs › ENTERASYS-RADIUS-ACCT-CLIENT-EXT-MIB › etsysRadiusAcctClientIntervalMinimum
etsysRadiusAcctClientIntervalMinimum
Module: ENTERASYS-RADIUS-ACCT-CLIENT-EXT-MIB
OID (symbolic): ENTERASYS-RADIUS-ACCT-CLIENT-EXT-MIB::etsysRadiusAcctClientIntervalMinimum
OID (numeric): 1.3.6.1.4.1.5624.1.2.27.1.3
Node type: OBJECT-TYPE
Type: Integer32
Access: read-write
Description: This indicates the minimum value in seconds between accounting interim updates supported by the managed entity. This parameter value is maintained across system reboots. If RADIUS Accounting is not enabled, this object is ignored.
What is etsysRadiusAcctClientIntervalMinimum?
This object defines the smallest interim-update interval, in seconds, that the RADIUS accounting client will honor. It acts as a floor that protects the device from being told to send interim updates too frequently, which could overload the RADIUS server or the switch itself. For instance, with the default of 600 seconds, if the configured update interval is set lower than that, the client silently falls back to sending updates no more often than every 600 seconds.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.5624.1.2.27.1.3 snmpwalk -v2c -c public <target> ENTERASYS-RADIUS-ACCT-CLIENT-EXT-MIB::etsysRadiusAcctClientIntervalMinimum
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.5624.1.2.27.1.3.1 snmpget -v2c -c public <target> ENTERASYS-RADIUS-ACCT-CLIENT-EXT-MIB::etsysRadiusAcctClientIntervalMinimum.1
Set instance 1 (SNMPv2c):
snmpset -v2c -c private <target> 1.3.6.1.4.1.5624.1.2.27.1.3.1 i <value>
SNMPv3 example:
snmpget -v3 -l authPriv -u snmpv3-user -a SHA -A "AuthPassword1" -x AES -X "PrivPassword1" <target> etsysRadiusAcctClientIntervalMinimum.1
Start monitoring Enterasys/Extreme Networks wireless switch/controller (RADIUS accounting client extensions) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the ENTERASYS-RADIUS-ACCT-CLIENT-EXT-MIB::etsysRadiusAcctClientIntervalMinimum OID value, configure state conditions and alerts, and monitor any Enterasys/Extreme Networks wireless switch/controller (RADIUS accounting client extensions) from a single console.
OID Breakdown
Upper-level ancestors (9 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.5624 | enterasys | ENTERASYS-MIB-NAMES |
| 1.3.6.1.4.1.5624.1 | etsysMibs | ENTERASYS-MIB-NAMES |
| 1.3.6.1.4.1.5624.1.2 | etsysModules | ENTERASYS-MIB-NAMES |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.5624.1.2.27 | etsysRadiusAcctClientMIB | ENTERASYS-RADIUS-ACCT-CLIENT-EXT-MIB |
| 1.3.6.1.4.1.5624.1.2.27.1 | etsysRadiusAcctClientMIBObjects | ENTERASYS-RADIUS-ACCT-CLIENT-EXT-MIB |
| 1.3.6.1.4.1.5624.1.2.27.1.3 | etsysRadiusAcctClientIntervalMinimum | ENTERASYS-RADIUS-ACCT-CLIENT-EXT-MIB |