DELL-NETWORKING-COPY-CONFIG-MIB :: copyDestFileName

MIB Reference — IPNetwork Monitor · Updated October 05, 2026

All MIBs › DELL-NETWORKING-COPY-CONFIG-MIB › copyDestFileName

copyDestFileName

Module: DELL-NETWORKING-COPY-CONFIG-MIB

OID (symbolic): DELL-NETWORKING-COPY-CONFIG-MIB::copyDestFileName

OID (numeric): 1.3.6.1.4.1.6027.3.5.1.1.1.1.7

Node type: OBJECT-TYPE

Type: DisplayString

Access: read-write

Description: Specifies the location of destination file.

If the copyDestFileType has the value of dellNetFile(1), it is expected that the dellNetCopyDestFileTyp and copyDestFileLocation must also be spcified. The three objects together will uniquely identify the source file.

If the copyDestFileLocation has the value of ftp(4) or scp(5), it is expected the login information liked copyServerAddress, copyUserName, and copyUserPassword also be spcified.

What is copyDestFileName?

This read-write DisplayString gives the name (including path, if applicable) of the destination file for a config-copy request. It is required together with copyDestFileType and copyDestFileLocation whenever copyDestFileType is dellNetFile, so the three objects jointly pin down exactly which file gets written. For example, an admin copying a trace log to a remote FTP server might set copyDestFileName to /usr/tester1/trace/backup/LP4-nvtrace-0.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.6027.3.5.1.1.1.1.7
snmpwalk -v2c -c public <target> DELL-NETWORKING-COPY-CONFIG-MIB::copyDestFileName

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.6027.3.5.1.1.1.1.7.1
snmpget -v2c -c public <target> DELL-NETWORKING-COPY-CONFIG-MIB::copyDestFileName.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.6027.3.5.1.1.1.1.7.1 s <value>

Start monitoring Dell Networking switch (config/firmware copy) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the DELL-NETWORKING-COPY-CONFIG-MIB::copyDestFileName OID value, configure state conditions and alerts, and monitor any Dell Networking switch (config/firmware copy) from a single console.

OID Breakdown

Upper-level ancestors (8 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.6027dellNetDELL-NETWORKING-SMI
1.3.6.1.4.1.6027.3dellNetMgmtDELL-NETWORKING-SMI
Numeric OIDNameModule
1.3.6.1.4.1.6027.3.5dellNetCopyConfigMibDELL-NETWORKING-COPY-CONFIG-MIB
1.3.6.1.4.1.6027.3.5.1dellNetCopyConfigObjectsDELL-NETWORKING-COPY-CONFIG-MIB
1.3.6.1.4.1.6027.3.5.1.1dellNetCopyConfigDELL-NETWORKING-COPY-CONFIG-MIB
1.3.6.1.4.1.6027.3.5.1.1.1dellNetCopyTableDELL-NETWORKING-COPY-CONFIG-MIB
1.3.6.1.4.1.6027.3.5.1.1.1.1dellNetCopyEntryDELL-NETWORKING-COPY-CONFIG-MIB
1.3.6.1.4.1.6027.3.5.1.1.1.1.7copyDestFileNameDELL-NETWORKING-COPY-CONFIG-MIB