DACS-MIB :: prtGenTsIConPrt

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsDACS-MIBprtGenTsIConPrt

prtGenTsIConPrt

Module: DACS-MIB

OID (symbolic): DACS-MIB::prtGenTsIConPrt

OID (numeric): 1.3.6.1.4.1.164.3.3.3.1.3.1.5

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-write

Description: This attribute indicates the internally (In Mux) connected port. The valid port number depends on the IO slot no., the installed card type and the port type: outside, inside, SP. * The outside ports will be the T1/E1 cards ports. The convention used will be (for DXC): - first two digits will be: (IO slot number+10) for a stand-alone unit, the IO slot will be considered 1. - last one/two digits will be the port number within the card, in odd numbers: port1 = 1 port2 = 3 port3 = 5 etc... Example: port2 of IO slot 11 will be: 213 . * The inside ports will be for example, the HS cards ports. The convention used will be (for DXC): - first two digits will be: (IO slot number+10) for a stand-alone unit, the IO slot will be considered 1. - last one/two digits will be the port number within the card, in even numbers: port1 = 2 port2 = 4 port3 = 6 etc... Example: port2 of IO slot 11 will be: 214 . * noConnection - will be indicated as 10 for DXC and FCD-E1/T1. - will be indicated as 100 for FCD-E1/I and SMODs. * Split TS (same TS is Split to several ports) - 11.

All HS port's timeslots must have the same destination port.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.164.3.3.3.1.3.1.5
snmpwalk -v2c -c public <target> DACS-MIB::prtGenTsIConPrt

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.164.3.3.3.1.3.1.5.1
snmpget -v2c -c public <target> DACS-MIB::prtGenTsIConPrt.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.164.3.3.3.1.3.1.5.1 i <value>

Start monitoring Digital Access Cross-Connect System (DACS/DSX device) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the DACS-MIB::prtGenTsIConPrt OID value, configure state conditions and alerts, and monitor any Digital Access Cross-Connect System (DACS/DSX device) from a single console.

OID Breakdown

Upper-level ancestors (6 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
Numeric OIDNameModule
1.3.6.1.4.1.164radDACS-MIB
1.3.6.1.4.1.164.3radWanDACS-MIB
1.3.6.1.4.1.164.3.3dacsMuxDACS-MIB
1.3.6.1.4.1.164.3.3.3prtDacsMuxDACS-MIB
1.3.6.1.4.1.164.3.3.3.1prtGenDACS-MIB
1.3.6.1.4.1.164.3.3.3.1.3prtGenTsTableDACS-MIB
1.3.6.1.4.1.164.3.3.3.1.3.1prtGenTsEntryDACS-MIB
1.3.6.1.4.1.164.3.3.3.1.3.1.5prtGenTsIConPrtDACS-MIB