All MIBs › DACS-MIB › prtExVc2TxBitCode
prtExVc2TxBitCode
Module: DACS-MIB
OID (symbolic): DACS-MIB::prtExVc2TxBitCode
OID (numeric): 1.3.6.1.4.1.164.3.2.3.2.5.1.20
Node type: OBJECT-TYPE
Type: OCTET STRING
Access: read-write
Description:
- - - For MP & FCD - - -
This object represents 4 parameters, by 2 Octets :
Tx D Bit Code-MSB nibble,
Tx C Bit Code- nibble,
Tx B Bit Code- nibble,
Tx A Bit Code-LSB nibble.
Each nibble:
0 hex = 0000 = Not Applicable
1 hex = 0001 = M lead
2 hex = 0010 = M lead inverse
3 hex = 0011 = Reverse Polarity
4 hex = 0100 = Metering Pulse
5 hex = 0101 = Forced 1
6 hex = 0110 = Forced 0
7-F hex - not used (invalid values)
This object will be RO if prtExVc2SigProfile is NOT manual.
- - - For WR II - - -
This object represents the following 4 parameters by 2 Octets:
1. On/Off hook signaling transmission mode from the FXS towards the T1/E1 (MSB nibble 1).
2. Default signaling bits that are not in use (nibble 2).
3. Ring Detection signaling transmission mode from the FXO towards the T1/E1(nibble 3).
4. M (Mouth) Signaling transmission mode from the E&M towards the T1/E1(LSB nibble 4).
Each nibble:
---------------------------------------------------------------------------------------
Value On/Off Hook Default sig. Ring Detect. M (Mouth)
---------------------------------------------------------------------------------------
0 hex = 0000 Not Applicable Not Applicable. Not Applicable Not Applicable
1 hex = 0001 Tx A bit Values 1-3 are Tx A bit Tx A bit
2 hex = 0010 Tx A bit inverse for On/Off Hook Tx A bit inv. Tx A bit inv.
3 hex = 0011 Tx B bit A,B,A Inv,B Inv. Tx B bit Tx B bit
4 hex = 0100 Tx B bit inverse Values 4-7 are Tx B bit inv. Tx B bit inv.
5 hex = 0101 not Used-invalid for On/Off Hook not Used-invalid not Used-invalid
6 hex = 0110 not Used-invalid A, A Inverse. not Used-invalid not Used-invalid
7 hex = 0111 not Used-invalid not Used-invalid not Used-invalid
8 hex = 1000 not Used-invalid Values 8-11 are not Used-invalid not Used-invalid
9 hex = 1001 not Used-invalid for On/Off Hook not Used-invalid not Used-invalid
A hex = 1010 not used-invalid B, B Inverse. not Used-invalid not Used-invalid
B hex = 1011 not used-invalid The Bits order: not Used-invalid not Used-invalid
C-F hex not used-invalid ABCD not Used-invalid not Used-invalid
Default value: 11 11 Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.164.3.2.3.2.5.1.20 snmpwalk -v2c -c public <target> DACS-MIB::prtExVc2TxBitCode
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.164.3.2.3.2.5.1.20.1 snmpget -v2c -c public <target> DACS-MIB::prtExVc2TxBitCode.1
Set instance 1 (SNMPv2c):
snmpset -v2c -c private <target> 1.3.6.1.4.1.164.3.2.3.2.5.1.20.1 s <value>
OID Breakdown
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | BIANCA-BRICK-PPP-MIB |
| 1.3.6 | dod | BIANCA-BRICK-PPP-MIB |
| 1.3.6.1 | internet | BIANCA-BRICK-PPP-MIB |
| 1.3.6.1.4 | private | BIANCA-BRICK-PPP-MIB |
| 1.3.6.1.4.1 | enterprises | ANIROOT-MIB |
| 1.3.6.1.4.1.164 | rad | DACS-MIB |
| 1.3.6.1.4.1.164.3 | radWan | DACS-MIB |
| 1.3.6.1.4.1.164.3.2 | muxHub | DACS-MIB |
| 1.3.6.1.4.1.164.3.2.3 | prtMux | DACS-MIB |
| 1.3.6.1.4.1.164.3.2.3.2 | cnfgPrtMux | DACS-MIB |
| 1.3.6.1.4.1.164.3.2.3.2.5 | prtVc2CnfgTable | DACS-MIB |
| 1.3.6.1.4.1.164.3.2.3.2.5.1 | prtVc2CnfgEntry | DACS-MIB |
| 1.3.6.1.4.1.164.3.2.3.2.5.1.20 | prtExVc2TxBitCode | DACS-MIB |