All MIBs › CXFrameRelay-MIB › frpSapErrorThreshold
frpSapErrorThreshold
Module: CXFrameRelay-MIB
OID (symbolic): CXFrameRelay-MIB::frpSapErrorThreshold
OID (numeric): 1.3.6.1.4.1.495.2.1.6.3.1.1.16
Node type: OBJECT-TYPE
Type: INTEGER
Access: read-write
Description: Determines the number of unanswered 'Status Enquiry' messages that can occur within the interval defined in object frpSapMonitoredEvents before the user side of the UNI (user to network interface) declares the interface to be down. The value of frpSapErrorThreshold must not be greater than the value of frpSapMonitoredEvents. This object is meaningful only if object frpSapType for this SAP is set to 'lower'.
OR
Determines the number of timeouts that can occur within the interval defined in frpSapMonitoredEvents as result of not receiving a 'Status Enquiry' from a user before the network side of the UNI (user to network interface) declares the interface to be down. This object is meaningful only if object frpSapType for this SAP is set to 'lower'.
Range of Values: 1-10
Default Value: 3
Configuration Changed: administrative
What is frpSapErrorThreshold?
Sets, from 1 to 10, how many unanswered (or, on the network side, unreceived) Status Enquiry messages within the frpSapMonitoredEvents window are tolerated before this SAP's UNI is declared down -- the N392 counter from ANSI T1.617 -- defaulting to 3. Its value must never exceed frpSapMonitoredEvents, and it only applies when frpSapType is 'lower'.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.495.2.1.6.3.1.1.16 snmpwalk -v2c -c public <target> CXFrameRelay-MIB::frpSapErrorThreshold
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.495.2.1.6.3.1.1.16.1 snmpget -v2c -c public <target> CXFrameRelay-MIB::frpSapErrorThreshold.1
Set instance 1 (SNMPv2c):
snmpset -v2c -c private <target> 1.3.6.1.4.1.495.2.1.6.3.1.1.16.1 i <value>
Start monitoring CX Memotec Frame Relay access device/multiplexer with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CXFrameRelay-MIB::frpSapErrorThreshold OID value, configure state conditions and alerts, and monitor any CX Memotec Frame Relay access device/multiplexer from a single console.
OID Breakdown
Upper-level ancestors (11 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.495 | memotec | MEMOTEC-SMI |
| 1.3.6.1.4.1.495.2 | memotecProducts | MEMOTEC-SMI |
| 1.3.6.1.4.1.495.2.1 | cxProduct | MEMOTEC-SMI |
| 1.3.6.1.4.1.495.2.1.6 | cxApplication | CXProduct-SMI |
| 1.3.6.1.4.1.495.2.1.6.3 | cxFrameRelay | CXProduct-SMI |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.495.2.1.6.3.1 | frpSapTable | CXFrameRelay-MIB |
| 1.3.6.1.4.1.495.2.1.6.3.1.1 | frpSapEntry | CXFrameRelay-MIB |
| 1.3.6.1.4.1.495.2.1.6.3.1.1.16 | frpSapErrorThreshold | CXFrameRelay-MIB |