All MIBs › CXFrameRelay-MIB › frpCircuitstatAlternateRouteState
frpCircuitstatAlternateRouteState
Module: CXFrameRelay-MIB
OID (symbolic): CXFrameRelay-MIB::frpCircuitstatAlternateRouteState
OID (numeric): 1.3.6.1.4.1.495.2.1.6.3.2.1.42
Node type: OBJECT-TYPE
Type: INTEGER
Access: read-only
Description: Indicates the current state of the virtual circuit's alternate route or pathway.
Options: noRoute (1): Virtual circuit has no associated alternate pathway
routeNotOperational (2): Alternate pathway of virtual circuit is not operational
routeOperational (3): Alternate pathway of virtual circuit is operational
alternateCircuit (4): This virtual circuit is an alternate circuit
Default Value: noRoute (1)
What is frpCircuitstatAlternateRouteState?
Reports the operational state of this circuit's alternate (backup) route -- noRoute, routeNotOperational, or routeOperational -- or alternateCircuit(4) if this row is itself acting as another circuit's alternate.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.495.2.1.6.3.2.1.42 snmpwalk -v2c -c public <target> CXFrameRelay-MIB::frpCircuitstatAlternateRouteState
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.495.2.1.6.3.2.1.42.1 snmpget -v2c -c public <target> CXFrameRelay-MIB::frpCircuitstatAlternateRouteState.1
Start monitoring CX Memotec Frame Relay access device/multiplexer with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CXFrameRelay-MIB::frpCircuitstatAlternateRouteState OID value, configure state conditions and alerts, and monitor any CX Memotec Frame Relay access device/multiplexer from a single console.
OID Breakdown
Upper-level ancestors (11 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.495 | memotec | MEMOTEC-SMI |
| 1.3.6.1.4.1.495.2 | memotecProducts | MEMOTEC-SMI |
| 1.3.6.1.4.1.495.2.1 | cxProduct | MEMOTEC-SMI |
| 1.3.6.1.4.1.495.2.1.6 | cxApplication | CXProduct-SMI |
| 1.3.6.1.4.1.495.2.1.6.3 | cxFrameRelay | CXProduct-SMI |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.495.2.1.6.3.2 | frpCircuitTable | CXFrameRelay-MIB |
| 1.3.6.1.4.1.495.2.1.6.3.2.1 | frpCircuitEntry | CXFrameRelay-MIB |
| 1.3.6.1.4.1.495.2.1.6.3.2.1.42 | frpCircuitstatAlternateRouteState | CXFrameRelay-MIB |