CXFrameRelay-MIB :: frpCircuitMulticastType

MIB Reference — IPNetwork Monitor · Updated October 05, 2026

All MIBs › CXFrameRelay-MIB › frpCircuitMulticastType

frpCircuitMulticastType

Module: CXFrameRelay-MIB

OID (symbolic): CXFrameRelay-MIB::frpCircuitMulticastType

OID (numeric): 1.3.6.1.4.1.495.2.1.6.3.2.1.25

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-only

Description: Determines member and service types of this virtual circuit when part of a multicast group.

Options: noMulticastAssociation (1): PVC is not part of multicast group

rootOneWay (2): PVC is a root member whose multicast server sends frames received from this root member only to route partners of the multicast group's active leaf members (one-way multicast service)

leafOneWay (3): PVC is a leaf member that cannot receive a root member's frames from a multicast server (one-way multicast service)

rootTwoWay (4): PVC is a root member whose multicast server sends frames received from this root member to this multicast group's active leaf members; the multicast server also sends frames received from any active leaf member to the root member (two-way multicast service)

leafTwoWay (5): PVC is a leaf member whose multicast server sends frames received from this leaf member to this multicast group's root member (two-way multicast service)

rootNWay (6): PVC is a root member whose multicast server sends frames received from this root member to this multicast group's other active root members; the multicast server also sends frames received from any other active root member to all other active root members (N-way multicast service)

rootTwoWaySinglePass (7): PVC is a root member whose multicast server sends frames received from this root member to this multicast group's first active leaf members found only; the multicast server also sends frames received from any active leaf member to the root member (two-way multicast service)

leafTwoWaySinglePass (8): PVC is a leaf member whose multicast server sends frames received from this leaf member to this multicast group's root member (two-way multicast service)

Default Value: noMulticastAssociation (1)

What is frpCircuitMulticastType?

Determines this circuit's role and service style within its multicast group -- root or leaf membership combined with one-way, two-way, N-way, or single-pass forwarding behavior -- or noMulticastAssociation(1), the default, if the circuit is not part of a multicast group at all.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.495.2.1.6.3.2.1.25
snmpwalk -v2c -c public <target> CXFrameRelay-MIB::frpCircuitMulticastType

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.495.2.1.6.3.2.1.25.1
snmpget -v2c -c public <target> CXFrameRelay-MIB::frpCircuitMulticastType.1

Start monitoring CX Memotec Frame Relay access device/multiplexer with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CXFrameRelay-MIB::frpCircuitMulticastType OID value, configure state conditions and alerts, and monitor any CX Memotec Frame Relay access device/multiplexer from a single console.

OID Breakdown

Upper-level ancestors (11 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.495memotecMEMOTEC-SMI
1.3.6.1.4.1.495.2memotecProductsMEMOTEC-SMI
1.3.6.1.4.1.495.2.1cxProductMEMOTEC-SMI
1.3.6.1.4.1.495.2.1.6cxApplicationCXProduct-SMI
1.3.6.1.4.1.495.2.1.6.3cxFrameRelayCXProduct-SMI
Numeric OIDNameModule
1.3.6.1.4.1.495.2.1.6.3.2frpCircuitTableCXFrameRelay-MIB
1.3.6.1.4.1.495.2.1.6.3.2.1frpCircuitEntryCXFrameRelay-MIB
1.3.6.1.4.1.495.2.1.6.3.2.1.25frpCircuitMulticastTypeCXFrameRelay-MIB