CXFrameRelay-MIB :: frpCircuitCIRManagement

MIB Reference — IPNetwork Monitor · Updated October 05, 2026

All MIBs › CXFrameRelay-MIB › frpCircuitCIRManagement

frpCircuitCIRManagement

Module: CXFrameRelay-MIB

OID (symbolic): CXFrameRelay-MIB::frpCircuitCIRManagement

OID (numeric): 1.3.6.1.4.1.495.2.1.6.3.2.1.8

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-write

Description: Determines whether CIR management is enabled for this virtual circuit.

Note: If CIR management is enabled, frpCircuitCommittedBurst, frpCircuitExcessBurst and frpCircuitCommittedInformationRate are used to control the information flow rate at inbound/outbound of the virtual circuit. If CIR management is enabled only for monitoring, these objects are used to gather statistics regarding information flow rate.

Options: disabled (1): congestion management is disabled

enabled-inbound (2): CIR management is enabled at inbound

monitor-inbound (3): CIR management is enabled at inbound for monitoring only

enabled-outbound (4): CIR management is enabled at outbound

Default Value: disabled (1)

Configuration Changed: operative

What is frpCircuitCIRManagement?

Controls how the committed-information-rate objects (frpCircuitCommittedBurst, frpCircuitExcessBurst, frpCircuitCommittedInformationRate) are applied to this circuit: disabled(1) turns CIR control off, enabled-inbound(2) and enabled-outbound(4) actively enforce the rate in that direction, and monitor-inbound(3) only gathers statistics without enforcing it. It defaults to disabled.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.495.2.1.6.3.2.1.8
snmpwalk -v2c -c public <target> CXFrameRelay-MIB::frpCircuitCIRManagement

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.495.2.1.6.3.2.1.8.1
snmpget -v2c -c public <target> CXFrameRelay-MIB::frpCircuitCIRManagement.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.495.2.1.6.3.2.1.8.1 i <value>

Start monitoring CX Memotec Frame Relay access device/multiplexer with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CXFrameRelay-MIB::frpCircuitCIRManagement OID value, configure state conditions and alerts, and monitor any CX Memotec Frame Relay access device/multiplexer from a single console.

OID Breakdown

Upper-level ancestors (11 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.495memotecMEMOTEC-SMI
1.3.6.1.4.1.495.2memotecProductsMEMOTEC-SMI
1.3.6.1.4.1.495.2.1cxProductMEMOTEC-SMI
1.3.6.1.4.1.495.2.1.6cxApplicationCXProduct-SMI
1.3.6.1.4.1.495.2.1.6.3cxFrameRelayCXProduct-SMI
Numeric OIDNameModule
1.3.6.1.4.1.495.2.1.6.3.2frpCircuitTableCXFrameRelay-MIB
1.3.6.1.4.1.495.2.1.6.3.2.1frpCircuitEntryCXFrameRelay-MIB
1.3.6.1.4.1.495.2.1.6.3.2.1.8frpCircuitCIRManagementCXFrameRelay-MIB