All MIBs › CXFrameRelay-MIB › frpCircuitAlternateSapNumber
frpCircuitAlternateSapNumber
Module: CXFrameRelay-MIB
OID (symbolic): CXFrameRelay-MIB::frpCircuitAlternateSapNumber
OID (numeric): 1.3.6.1.4.1.495.2.1.6.3.2.1.22
Node type: OBJECT-TYPE
Type: INTEGER
Access: read-write
Description: Indicates an alternative companion SAP in the Frame Relay software layer involved, together with 'frpCircuitAlternativeDlci', in establishing one of 1,022 possible secondary virtual circuits for this SAP.
Options: 1-7: (CX900's BOP- or BCM-related lower SAPs)
1-16: (CX1000's BOP- or DXI-related lower SAPs)
17-32: (CX1000's GFF-related lower SAPs)
40: (GMF-related upper SAP)
41: (FRIM-related upper SAP)
Default Value: none
Configuration Changed: operative
What is frpCircuitAlternateSapNumber?
Identifies, together with frpCircuitAlternateDlci, an alternative companion SAP used to build a secondary path for this virtual circuit, providing a backup route if the primary companion path fails; defaults to 0 (none set).
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.495.2.1.6.3.2.1.22 snmpwalk -v2c -c public <target> CXFrameRelay-MIB::frpCircuitAlternateSapNumber
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.495.2.1.6.3.2.1.22.1 snmpget -v2c -c public <target> CXFrameRelay-MIB::frpCircuitAlternateSapNumber.1
Set instance 1 (SNMPv2c):
snmpset -v2c -c private <target> 1.3.6.1.4.1.495.2.1.6.3.2.1.22.1 i <value>
Start monitoring CX Memotec Frame Relay access device/multiplexer with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CXFrameRelay-MIB::frpCircuitAlternateSapNumber OID value, configure state conditions and alerts, and monitor any CX Memotec Frame Relay access device/multiplexer from a single console.
OID Breakdown
Upper-level ancestors (11 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.495 | memotec | MEMOTEC-SMI |
| 1.3.6.1.4.1.495.2 | memotecProducts | MEMOTEC-SMI |
| 1.3.6.1.4.1.495.2.1 | cxProduct | MEMOTEC-SMI |
| 1.3.6.1.4.1.495.2.1.6 | cxApplication | CXProduct-SMI |
| 1.3.6.1.4.1.495.2.1.6.3 | cxFrameRelay | CXProduct-SMI |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.495.2.1.6.3.2 | frpCircuitTable | CXFrameRelay-MIB |
| 1.3.6.1.4.1.495.2.1.6.3.2.1 | frpCircuitEntry | CXFrameRelay-MIB |
| 1.3.6.1.4.1.495.2.1.6.3.2.1.22 | frpCircuitAlternateSapNumber | CXFrameRelay-MIB |