CXAsync-MIB :: asySapRxThruputClass

MIB Reference — IPNetwork Monitor · Updated October 05, 2026

All MIBs › CXAsync-MIB › asySapRxThruputClass

asySapRxThruputClass

Module: CXAsync-MIB

OID (symbolic): CXAsync-MIB::asySapRxThruputClass

OID (numeric): 1.3.6.1.4.1.495.2.1.6.30.20.1.10

Node type: OBJECT-TYPE

Type: ThruputClass

Access: read-write

Description: Defines the default receive throughput class that is used at this SAP (service access point).

Range of Values: 75 - 64000 bps

Default Value: 9600 bps

Configuration Changed: Operative

What is asySapRxThruputClass?

This read-write value (75-64000 bps, default 9600) sets the default receive throughput class negotiated for calls at this SAP, per CCITT X.25 Table 30 -- an admin lowers or raises it to match the expected inbound data rate of attached DTEs.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.495.2.1.6.30.20.1.10
snmpwalk -v2c -c public <target> CXAsync-MIB::asySapRxThruputClass

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.495.2.1.6.30.20.1.10.1
snmpget -v2c -c public <target> CXAsync-MIB::asySapRxThruputClass.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.495.2.1.6.30.20.1.10.1 s <value>

Start monitoring Memotec CX-series statistical multiplexer/X.25 PAD device with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CXAsync-MIB::asySapRxThruputClass OID value, configure state conditions and alerts, and monitor any Memotec CX-series statistical multiplexer/X.25 PAD device from a single console.

OID Breakdown

Upper-level ancestors (11 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.495memotecMEMOTEC-SMI
1.3.6.1.4.1.495.2memotecProductsMEMOTEC-SMI
1.3.6.1.4.1.495.2.1cxProductMEMOTEC-SMI
1.3.6.1.4.1.495.2.1.6cxApplicationCXProduct-SMI
1.3.6.1.4.1.495.2.1.6.30cxAsyncCXProduct-SMI
Numeric OIDNameModule
1.3.6.1.4.1.495.2.1.6.30.20asySapTableCXAsync-MIB
1.3.6.1.4.1.495.2.1.6.30.20.1asySapEntryCXAsync-MIB
1.3.6.1.4.1.495.2.1.6.30.20.1.10asySapRxThruputClassCXAsync-MIB