Type: YesNo

Access: read-write

Description: Authorizes the DCE (Async application) to transmit incoming calls to the DTE (Async user) that requested the reverse charging, if reverse charging acceptance is allowed. If acceptance is not allowed, the DCE (Async application) will not transmit the incoming calls to the DTE which requested the reverse charging.

Options: Yes

No

Default Value: No

Configuration Changed: Operative

What is asySapReverseChargingAcceptance?

This read-write Yes/No flag (default No) authorizes the SAP to accept reverse-charging (collect call style) incoming X.25 calls per CCITT X.25 6.19; an admin enables it only for ports that should let callers bill the connection to this system.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.495.2.1.6.30.20.1.19
snmpwalk -v2c -c public <target> CXAsync-MIB::asySapReverseChargingAcceptance

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.495.2.1.6.30.20.1.19.1
snmpget -v2c -c public <target> CXAsync-MIB::asySapReverseChargingAcceptance.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.495.2.1.6.30.20.1.19.1 s <value>

Start monitoring Memotec CX-series statistical multiplexer/X.25 PAD device with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CXAsync-MIB::asySapReverseChargingAcceptance OID value, configure state conditions and alerts, and monitor any Memotec CX-series statistical multiplexer/X.25 PAD device from a single console.

OID Breakdown

Upper-level ancestors (11 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.495memotecMEMOTEC-SMI
1.3.6.1.4.1.495.2memotecProductsMEMOTEC-SMI
1.3.6.1.4.1.495.2.1cxProductMEMOTEC-SMI
1.3.6.1.4.1.495.2.1.6cxApplicationCXProduct-SMI
1.3.6.1.4.1.495.2.1.6.30cxAsyncCXProduct-SMI
Numeric OIDNameModule
1.3.6.1.4.1.495.2.1.6.30.20asySapTableCXAsync-MIB
1.3.6.1.4.1.495.2.1.6.30.20.1asySapEntryCXAsync-MIB
1.3.6.1.4.1.495.2.1.6.30.20.1.19asySapReverseChargingAcceptanceCXAsync-MIB