CXAsync-MIB :: asySapProfParameter12

MIB Reference — IPNetwork Monitor · Updated October 05, 2026

All MIBs › CXAsync-MIB › asySapProfParameter12

asySapProfParameter12

Module: CXAsync-MIB

OID (symbolic): CXAsync-MIB::asySapProfParameter12

OID (numeric): 1.3.6.1.4.1.495.2.1.6.30.22.1.16

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-write

Description: Defines the X.3 parameter 12, Flow control of the PAD. This parameter allows for flow control between the start-stop mode DTE (user) and the PAD.

Options: 0: No use of X-ON (DC1) and X-OFF (DC3) for flow control 1: Use of X-ON (DC1) and X-OFF (DC3) for flow control

Default Value: No use of X-ON (DC1) and X-OFF (DC3) for flow control

Configuration Changed: Operative

Note: Object asyProfParameter25, Flow control on character to PAD, and object asyProfParameter26, Flow control off character to PAD, are allowed only if this object is set to No use of X-ON (DC1) and X-OFF (DC3).

What is asySapProfParameter12?

X.3 parameter 12 (PAD-side XON/XOFF flow control) here is the operational value currently in effect at this specific SAP (as opposed to the stored profile template) -- it (0=off, 1=on, default off) controls flow control between the terminal and the PAD in the opposite direction from parameter 5.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.495.2.1.6.30.22.1.16
snmpwalk -v2c -c public <target> CXAsync-MIB::asySapProfParameter12

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.495.2.1.6.30.22.1.16.1
snmpget -v2c -c public <target> CXAsync-MIB::asySapProfParameter12.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.495.2.1.6.30.22.1.16.1 i <value>

Start monitoring Memotec CX-series statistical multiplexer/X.25 PAD device with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CXAsync-MIB::asySapProfParameter12 OID value, configure state conditions and alerts, and monitor any Memotec CX-series statistical multiplexer/X.25 PAD device from a single console.

OID Breakdown

Upper-level ancestors (11 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.495memotecMEMOTEC-SMI
1.3.6.1.4.1.495.2memotecProductsMEMOTEC-SMI
1.3.6.1.4.1.495.2.1cxProductMEMOTEC-SMI
1.3.6.1.4.1.495.2.1.6cxApplicationCXProduct-SMI
1.3.6.1.4.1.495.2.1.6.30cxAsyncCXProduct-SMI
Numeric OIDNameModule
1.3.6.1.4.1.495.2.1.6.30.22asySapProfTableCXAsync-MIB
1.3.6.1.4.1.495.2.1.6.30.22.1asySapProfEntryCXAsync-MIB
1.3.6.1.4.1.495.2.1.6.30.22.1.16asySapProfParameter12CXAsync-MIB