CXAsync-MIB :: asyProfParameter7

MIB Reference — IPNetwork Monitor · Updated October 05, 2026

All MIBs › CXAsync-MIB › asyProfParameter7

asyProfParameter7

Module: CXAsync-MIB

OID (symbolic): CXAsync-MIB::asyProfParameter7

OID (numeric): 1.3.6.1.4.1.495.2.1.6.30.21.1.11

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-write

Description: Defines the X.3 parameter 7, Selection of operation of the PAD on receipt of a break signal from the start-stop mode DTE. This parameter allows the selection of the operation of the PAD after the receipt of a break signal from the start-stop mode DTE (user).

Range of Values: 0: Nothing 1: Interrupt 2: Reset 4: Send to DTE an indication of break PAD message 5: Interrupt and indication of break 8: Escape from data transfer state 16: Discard output, to start-stop mode DTE 21: Discard output, interrupt and indication of break

Default Value: 0

Configuration Changed: Operative

What is asyProfParameter7?

X.3 parameter 7 (behavior on receipt of a break signal) in this stored X.3 profile (0=nothing, 1=interrupt, 2=reset, 4=send break indication, 5/8/16/21=combinations, default 0) selects what the PAD does when the terminal sends a serial break; an admin edits it here to change how any SAP loading this profile (via asySapX3Profile) behaves for PAD sessions.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.495.2.1.6.30.21.1.11
snmpwalk -v2c -c public <target> CXAsync-MIB::asyProfParameter7

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.495.2.1.6.30.21.1.11.1
snmpget -v2c -c public <target> CXAsync-MIB::asyProfParameter7.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.495.2.1.6.30.21.1.11.1 i <value>

Start monitoring Memotec CX-series statistical multiplexer/X.25 PAD device with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CXAsync-MIB::asyProfParameter7 OID value, configure state conditions and alerts, and monitor any Memotec CX-series statistical multiplexer/X.25 PAD device from a single console.

OID Breakdown

Upper-level ancestors (11 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.495memotecMEMOTEC-SMI
1.3.6.1.4.1.495.2memotecProductsMEMOTEC-SMI
1.3.6.1.4.1.495.2.1cxProductMEMOTEC-SMI
1.3.6.1.4.1.495.2.1.6cxApplicationCXProduct-SMI
1.3.6.1.4.1.495.2.1.6.30cxAsyncCXProduct-SMI
Numeric OIDNameModule
1.3.6.1.4.1.495.2.1.6.30.21asyProfTableCXAsync-MIB
1.3.6.1.4.1.495.2.1.6.30.21.1asyProfEntryCXAsync-MIB
1.3.6.1.4.1.495.2.1.6.30.21.1.11asyProfParameter7CXAsync-MIB