All MIBs › CPQSM2-MIB › cpqSm2CntlrExternalPowerCableStatus
cpqSm2CntlrExternalPowerCableStatus
Module: CPQSM2-MIB
OID (symbolic): CPQSM2-MIB::cpqSm2CntlrExternalPowerCableStatus
OID (numeric): 1.3.6.1.4.1.232.9.2.2.25
Node type: OBJECT-TYPE
Type: INTEGER
Access: read-only
Description: Remote Insight External Power Cable Status.
The following values are defined:
other(1) The Insight Agent is unable to determine if the External or Internal power cable connections to the Remote Insight.
externallyConnected(2) Just External power cable is connected to the Remote Insight.
disconnected(3) Both External and Internal power cables are disconnected from the Remote Insight.
internallyConnected(4) Just Internal power cable is connected to the Remote Insight.
externallyAndInternallyConnected(5) Both External and Internal power cables are connected to the Remote Insight.
notApplicable(6) Not Applicable.
What is cpqSm2CntlrExternalPowerCableStatus?
This read-only INTEGER reports the combination of external and internal power cable connections feeding the Remote Insight/iLO controller (externally connected, disconnected, internally connected, or both). An administrator cares because it shows which power source is actually wired to the management controller, and a disconnected value means the board has no monitored power link. For example, a technician verifies this OID reads externallyAndInternallyConnected(5) to confirm redundant power wiring is complete on a newly installed RILOE board.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.232.9.2.2.25 snmpwalk -v2c -c public <target> CPQSM2-MIB::cpqSm2CntlrExternalPowerCableStatus
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.232.9.2.2.25.1 snmpget -v2c -c public <target> CPQSM2-MIB::cpqSm2CntlrExternalPowerCableStatus.1
Start monitoring Compaq/HP ProLiant server (iLO management board) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CPQSM2-MIB::cpqSm2CntlrExternalPowerCableStatus OID value, configure state conditions and alerts, and monitor any Compaq/HP ProLiant server (iLO management board) from a single console.
OID Breakdown
Upper-level ancestors (7 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.232 | compaq | COMPAQ-ID-REC-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.232.9 | cpqSm2 | CPQSM2-MIB |
| 1.3.6.1.4.1.232.9.2 | cpqSm2Component | CPQSM2-MIB |
| 1.3.6.1.4.1.232.9.2.2 | cpqSm2Cntlr | CPQSM2-MIB |
| 1.3.6.1.4.1.232.9.2.2.25 | cpqSm2CntlrExternalPowerCableStatus | CPQSM2-MIB |