CPQSCSI-MIB :: cpqTapeLibraryHotSwap

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsCPQSCSI-MIBcpqTapeLibraryHotSwap

cpqTapeLibraryHotSwap

Module: CPQSCSI-MIB

OID (symbolic): CPQSCSI-MIB::cpqTapeLibraryHotSwap

OID (numeric): 1.3.6.1.4.1.232.5.4.3.1.1.16

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-only

Description: Tape Library Hot Swap Status.

Hot swap status denotes the presence of hot swappable internal components such as drives, fans, power supplies, etc. The library hot swap status can be in one of the following states:

other(1) The library hot swap status is unknown.

notSupported(2) Indicates that the library cannot detect or report hot swap status.

capable(3) Indicates that the library is capable of detecting and reporting hot swappable internal components and has at least one hot swappable component.

notCapable(4) Indicates that the library is capable of detecting and reporting hot swappable internal components but there are no hot swappable components installed.

What is cpqTapeLibraryHotSwap?

This enumerated value reports whether the tape library supports hot-swapping internal components like drives, fans, or power supplies, reporting other, notSupported, capable, or notCapable. Admins use it to know whether a failed internal component in the library can be replaced without powering the whole unit down. For example, a library reporting hotSwap capable lets a technician replace a failed fan module without shutting down the library.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.232.5.4.3.1.1.16
snmpwalk -v2c -c public <target> CPQSCSI-MIB::cpqTapeLibraryHotSwap

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.232.5.4.3.1.1.16.1
snmpget -v2c -c public <target> CPQSCSI-MIB::cpqTapeLibraryHotSwap.1

Start monitoring Compaq (HP) server (SCSI storage controller) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CPQSCSI-MIB::cpqTapeLibraryHotSwap OID value, configure state conditions and alerts, and monitor any Compaq (HP) server (SCSI storage controller) from a single console.

OID Breakdown

Upper-level ancestors (7 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.232compaqCOMPAQ-ID-REC-MIB
Numeric OIDNameModule
1.3.6.1.4.1.232.5cpqScsiCPQSCSI-MIB
1.3.6.1.4.1.232.5.4cpqTapeComponentCPQSCSI-MIB
1.3.6.1.4.1.232.5.4.3cpqTapeLibraryCPQSCSI-MIB
1.3.6.1.4.1.232.5.4.3.1cpqTapeLibraryTableCPQSCSI-MIB
1.3.6.1.4.1.232.5.4.3.1.1cpqTapeLibraryEntryCPQSCSI-MIB
1.3.6.1.4.1.232.5.4.3.1.1.16cpqTapeLibraryHotSwapCPQSCSI-MIB