CPQIDA-MIB :: cpqDaPhyDrvSpinupRetries

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsCPQIDA-MIBcpqDaPhyDrvSpinupRetries

cpqDaPhyDrvSpinupRetries

Module: CPQIDA-MIB

OID (symbolic): CPQIDA-MIB::cpqDaPhyDrvSpinupRetries

OID (numeric): 1.3.6.1.4.1.232.3.2.5.1.1.28

Node type: OBJECT-TYPE

Type: Counter

Access: read-only

Description: Spin up Retries.

The number of times that a physical drive had to retry to spin up before successfully achieving operating speed during the reference time (phyDrvRefTime). This value represents the spin-up retries that occurred since the last time you turned on the monitored system.

If you suspect a problem, schedule server down time to run diagnostics verify that a problem exists.

What is cpqDaPhyDrvSpinupRetries?

cpqDaPhyDrvSpinupRetries counts how many times a physical drive had to retry before successfully reaching full operating speed since the monitored system was last powered on. A nonzero and growing value suggests the drive's spindle motor is struggling to start reliably, which often precedes an outright spin-up failure. For example, an admin who sees this counter jump from 0 to several retries after a routine reboot would schedule downtime to run diagnostics on that drive.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.232.3.2.5.1.1.28
snmpwalk -v2c -c public <target> CPQIDA-MIB::cpqDaPhyDrvSpinupRetries

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.232.3.2.5.1.1.28.1
snmpget -v2c -c public <target> CPQIDA-MIB::cpqDaPhyDrvSpinupRetries.1

Start monitoring Compaq/HP ProLiant server (Smart Array/Intelligent Drive Array RAID controller) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CPQIDA-MIB::cpqDaPhyDrvSpinupRetries OID value, configure state conditions and alerts, and monitor any Compaq/HP ProLiant server (Smart Array/Intelligent Drive Array RAID controller) from a single console.

OID Breakdown

Upper-level ancestors (7 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.232compaqCOMPAQ-ID-REC-MIB
Numeric OIDNameModule
1.3.6.1.4.1.232.3cpqDriveArrayCPQIDA-MIB
1.3.6.1.4.1.232.3.2cpqDaComponentCPQIDA-MIB
1.3.6.1.4.1.232.3.2.5cpqDaPhyDrvCPQIDA-MIB
1.3.6.1.4.1.232.3.2.5.1cpqDaPhyDrvTableCPQIDA-MIB
1.3.6.1.4.1.232.3.2.5.1.1cpqDaPhyDrvEntryCPQIDA-MIB
1.3.6.1.4.1.232.3.2.5.1.1.28cpqDaPhyDrvSpinupRetriesCPQIDA-MIB