All MIBs › CPQIDA-MIB › cpqDaPhyDrvSpinupRetries
cpqDaPhyDrvSpinupRetries
Module: CPQIDA-MIB
OID (symbolic): CPQIDA-MIB::cpqDaPhyDrvSpinupRetries
OID (numeric): 1.3.6.1.4.1.232.3.2.5.1.1.28
Node type: OBJECT-TYPE
Type: Counter
Access: read-only
Description: Spin up Retries.
The number of times that a physical drive had to retry to spin up before successfully achieving operating speed during the reference time (phyDrvRefTime). This value represents the spin-up retries that occurred since the last time you turned on the monitored system.
If you suspect a problem, schedule server down time to run diagnostics verify that a problem exists.
What is cpqDaPhyDrvSpinupRetries?
cpqDaPhyDrvSpinupRetries counts how many times a physical drive had to retry before successfully reaching full operating speed since the monitored system was last powered on. A nonzero and growing value suggests the drive's spindle motor is struggling to start reliably, which often precedes an outright spin-up failure. For example, an admin who sees this counter jump from 0 to several retries after a routine reboot would schedule downtime to run diagnostics on that drive.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.232.3.2.5.1.1.28 snmpwalk -v2c -c public <target> CPQIDA-MIB::cpqDaPhyDrvSpinupRetries
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.232.3.2.5.1.1.28.1 snmpget -v2c -c public <target> CPQIDA-MIB::cpqDaPhyDrvSpinupRetries.1
Start monitoring Compaq/HP ProLiant server (Smart Array/Intelligent Drive Array RAID controller) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CPQIDA-MIB::cpqDaPhyDrvSpinupRetries OID value, configure state conditions and alerts, and monitor any Compaq/HP ProLiant server (Smart Array/Intelligent Drive Array RAID controller) from a single console.
OID Breakdown
Upper-level ancestors (7 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.232 | compaq | COMPAQ-ID-REC-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.232.3 | cpqDriveArray | CPQIDA-MIB |
| 1.3.6.1.4.1.232.3.2 | cpqDaComponent | CPQIDA-MIB |
| 1.3.6.1.4.1.232.3.2.5 | cpqDaPhyDrv | CPQIDA-MIB |
| 1.3.6.1.4.1.232.3.2.5.1 | cpqDaPhyDrvTable | CPQIDA-MIB |
| 1.3.6.1.4.1.232.3.2.5.1.1 | cpqDaPhyDrvEntry | CPQIDA-MIB |
| 1.3.6.1.4.1.232.3.2.5.1.1.28 | cpqDaPhyDrvSpinupRetries | CPQIDA-MIB |