CPQIDA-MIB :: cpqDaPhyDrvSenseCode

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsCPQIDA-MIBcpqDaPhyDrvSenseCode

cpqDaPhyDrvSenseCode

Module: CPQIDA-MIB

OID (symbolic): CPQIDA-MIB::cpqDaPhyDrvSenseCode

OID (numeric): 1.3.6.1.4.1.232.3.2.5.2.1.10

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-only

Description: Physical Drive Error Log Sense Code.

This is the SCSI Sense Code associated with the error log entry. For further specifications consult a SCSI-2 logical specification or other SCSI reference.

What is cpqDaPhyDrvSenseCode?

cpqDaPhyDrvSenseCode reports the SCSI Sense Code associated with a physical drive error log entry, per the SCSI-2 specification. This code, read alongside the sense key and qualifier, tells an admin the specific reason the drive reported an error for a given command. For example, a support engineer diagnosing repeated errors on one drive would decode this sense code against SCSI-2 documentation to confirm whether the fault is a medium error, a hardware fault, or something else.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.232.3.2.5.2.1.10
snmpwalk -v2c -c public <target> CPQIDA-MIB::cpqDaPhyDrvSenseCode

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.232.3.2.5.2.1.10.1
snmpget -v2c -c public <target> CPQIDA-MIB::cpqDaPhyDrvSenseCode.1

Start monitoring Compaq/HP ProLiant server (Smart Array/Intelligent Drive Array RAID controller) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CPQIDA-MIB::cpqDaPhyDrvSenseCode OID value, configure state conditions and alerts, and monitor any Compaq/HP ProLiant server (Smart Array/Intelligent Drive Array RAID controller) from a single console.

OID Breakdown

Upper-level ancestors (7 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.232compaqCOMPAQ-ID-REC-MIB
Numeric OIDNameModule
1.3.6.1.4.1.232.3cpqDriveArrayCPQIDA-MIB
1.3.6.1.4.1.232.3.2cpqDaComponentCPQIDA-MIB
1.3.6.1.4.1.232.3.2.5cpqDaPhyDrvCPQIDA-MIB
1.3.6.1.4.1.232.3.2.5.2cpqDaPhyDrvErrTableCPQIDA-MIB
1.3.6.1.4.1.232.3.2.5.2.1cpqDaPhyDrvErrEntryCPQIDA-MIB
1.3.6.1.4.1.232.3.2.5.2.1.10cpqDaPhyDrvSenseCodeCPQIDA-MIB