CPQIDA-MIB :: cpqDaPhyDrvOtherTimeouts

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsCPQIDA-MIBcpqDaPhyDrvOtherTimeouts

cpqDaPhyDrvOtherTimeouts

Module: CPQIDA-MIB

OID (symbolic): CPQIDA-MIB::cpqDaPhyDrvOtherTimeouts

OID (numeric): 1.3.6.1.4.1.232.3.2.5.1.1.27

Node type: OBJECT-TYPE

Type: Counter

Access: read-only

Description: Other Timeouts.

The number of times that a physical drive did not respond with an interrupt within a controller-defined period of time after a command had been issued during the reference time (phyDrvRefTime). This does not include DRQ timeouts.

If you suspect a problem, complete the following steps for the monitored system:

1. Check the cables connecting the drive to ensure that they are intact.

2. If the cables are properly connected, schedule server down time to run diagnostics to verify that a problem exists.

What is cpqDaPhyDrvOtherTimeouts?

cpqDaPhyDrvOtherTimeouts counts times a physical drive failed to interrupt the controller within its expected time window after a command was issued, excluding DRQ timeouts specifically. Because this is a separate timeout category from DRQ timeouts, its increase points more broadly to command-completion problems that could stem from cabling, the drive itself, or bus contention. As an example, if this counter climbs on a drive that also shows normal DRQ timeout counts, an admin would suspect a broader responsiveness issue with that drive rather than the specific DRQ handshake.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.232.3.2.5.1.1.27
snmpwalk -v2c -c public <target> CPQIDA-MIB::cpqDaPhyDrvOtherTimeouts

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.232.3.2.5.1.1.27.1
snmpget -v2c -c public <target> CPQIDA-MIB::cpqDaPhyDrvOtherTimeouts.1

Start monitoring Compaq/HP ProLiant server (Smart Array/Intelligent Drive Array RAID controller) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CPQIDA-MIB::cpqDaPhyDrvOtherTimeouts OID value, configure state conditions and alerts, and monitor any Compaq/HP ProLiant server (Smart Array/Intelligent Drive Array RAID controller) from a single console.

OID Breakdown

Upper-level ancestors (7 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.232compaqCOMPAQ-ID-REC-MIB
Numeric OIDNameModule
1.3.6.1.4.1.232.3cpqDriveArrayCPQIDA-MIB
1.3.6.1.4.1.232.3.2cpqDaComponentCPQIDA-MIB
1.3.6.1.4.1.232.3.2.5cpqDaPhyDrvCPQIDA-MIB
1.3.6.1.4.1.232.3.2.5.1cpqDaPhyDrvTableCPQIDA-MIB
1.3.6.1.4.1.232.3.2.5.1.1cpqDaPhyDrvEntryCPQIDA-MIB