CPQIDA-MIB :: cpqDaPhyDrvOtherTimeouts

MIB Reference — IPNetwork Monitor

All MIBsCPQIDA-MIBcpqDaPhyDrvOtherTimeouts

cpqDaPhyDrvOtherTimeouts

Module: CPQIDA-MIB

OID (symbolic): CPQIDA-MIB::cpqDaPhyDrvOtherTimeouts

OID (numeric): 1.3.6.1.4.1.232.3.2.5.1.1.27

Node type: OBJECT-TYPE

Type: Counter

Access: read-only

Description:

Other Timeouts.

The number of times that a physical drive did not respond with an interrupt within a controller-defined period of time after a command had been issued during the reference time (phyDrvRefTime). This does not include DRQ timeouts.

If you suspect a problem, complete the following steps for the monitored system:

1. Check the cables connecting the drive to ensure that they are intact.

2. If the cables are properly connected, schedule server down time to run diagnostics to verify that a problem exists.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.232.3.2.5.1.1.27
snmpwalk -v2c -c public <target> CPQIDA-MIB::cpqDaPhyDrvOtherTimeouts

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.232.3.2.5.1.1.27.1
snmpget -v2c -c public <target> CPQIDA-MIB::cpqDaPhyDrvOtherTimeouts.1

OID Breakdown

Numeric OIDNameModule
1isoLANART-AGENT
1.3orgBIANCA-BRICK-PPP-MIB
1.3.6dodBIANCA-BRICK-PPP-MIB
1.3.6.1internetBIANCA-BRICK-PPP-MIB
1.3.6.1.4privateBIANCA-BRICK-PPP-MIB
1.3.6.1.4.1enterprisesANIROOT-MIB
1.3.6.1.4.1.232compaqCOMPAQ-ID-REC-MIB
1.3.6.1.4.1.232.3cpqDriveArrayCPQIDA-MIB
1.3.6.1.4.1.232.3.2cpqDaComponentCPQIDA-MIB
1.3.6.1.4.1.232.3.2.5cpqDaPhyDrvCPQIDA-MIB
1.3.6.1.4.1.232.3.2.5.1cpqDaPhyDrvTableCPQIDA-MIB
1.3.6.1.4.1.232.3.2.5.1.1cpqDaPhyDrvEntryCPQIDA-MIB
1.3.6.1.4.1.232.3.2.5.1.1.27cpqDaPhyDrvOtherTimeoutsCPQIDA-MIB