CPQIDA-MIB :: cpqDaPhyDrvDrqTimeouts

MIB Reference — IPNetwork Monitor

All MIBsCPQIDA-MIBcpqDaPhyDrvDrqTimeouts

cpqDaPhyDrvDrqTimeouts

Module: CPQIDA-MIB

OID (symbolic): CPQIDA-MIB::cpqDaPhyDrvDrqTimeouts

OID (numeric): 1.3.6.1.4.1.232.3.2.5.1.1.26

Node type: OBJECT-TYPE

Type: Counter

Access: read-only

Description:

DRQ Timeouts.

The number of times that a physical drive continued to request data, but did not get a command completion during the reference time (phyDrvRefTime). This value increases every time a DRQ timeout occurs for the physical drive.

A defective drive or cable may cause DRQ timeouts to occur. If you see an increase in these errors, complete the following steps for the monitored system:

1. Check the cables connecting the drive to ensure that they are intact.

2. If the cables are properly connected, schedule server down time to run diagnostics to verify that a problem exists.

If the value is not supported, it is set to 4,294,967,295.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.232.3.2.5.1.1.26
snmpwalk -v2c -c public <target> CPQIDA-MIB::cpqDaPhyDrvDrqTimeouts

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.232.3.2.5.1.1.26.1
snmpget -v2c -c public <target> CPQIDA-MIB::cpqDaPhyDrvDrqTimeouts.1

OID Breakdown

Numeric OIDNameModule
1isoLANART-AGENT
1.3orgBIANCA-BRICK-PPP-MIB
1.3.6dodBIANCA-BRICK-PPP-MIB
1.3.6.1internetBIANCA-BRICK-PPP-MIB
1.3.6.1.4privateBIANCA-BRICK-PPP-MIB
1.3.6.1.4.1enterprisesANIROOT-MIB
1.3.6.1.4.1.232compaqCOMPAQ-ID-REC-MIB
1.3.6.1.4.1.232.3cpqDriveArrayCPQIDA-MIB
1.3.6.1.4.1.232.3.2cpqDaComponentCPQIDA-MIB
1.3.6.1.4.1.232.3.2.5cpqDaPhyDrvCPQIDA-MIB
1.3.6.1.4.1.232.3.2.5.1cpqDaPhyDrvTableCPQIDA-MIB
1.3.6.1.4.1.232.3.2.5.1.1cpqDaPhyDrvEntryCPQIDA-MIB
1.3.6.1.4.1.232.3.2.5.1.1.26cpqDaPhyDrvDrqTimeoutsCPQIDA-MIB