Description:
DRQ Timeouts.
The number of times that a physical drive continued to request data, but did not get a command completion during the reference time (phyDrvRefTime). This value increases every time a DRQ timeout occurs for the physical drive.
A defective drive or cable may cause DRQ timeouts to occur. If you see an increase in these errors, complete the following steps for the monitored system:
1. Check the cables connecting the drive to ensure that they are intact.
2. If the cables are properly connected, schedule server down time to run diagnostics to verify that a problem exists.
If the value is not supported, it is set to 4,294,967,295.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.232.3.2.5.1.1.26 snmpwalk -v2c -c public <target> CPQIDA-MIB::cpqDaPhyDrvDrqTimeouts
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.232.3.2.5.1.1.26.1 snmpget -v2c -c public <target> CPQIDA-MIB::cpqDaPhyDrvDrqTimeouts.1
OID Breakdown
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | BIANCA-BRICK-PPP-MIB |
| 1.3.6 | dod | BIANCA-BRICK-PPP-MIB |
| 1.3.6.1 | internet | BIANCA-BRICK-PPP-MIB |
| 1.3.6.1.4 | private | BIANCA-BRICK-PPP-MIB |
| 1.3.6.1.4.1 | enterprises | ANIROOT-MIB |
| 1.3.6.1.4.1.232 | compaq | COMPAQ-ID-REC-MIB |
| 1.3.6.1.4.1.232.3 | cpqDriveArray | CPQIDA-MIB |
| 1.3.6.1.4.1.232.3.2 | cpqDaComponent | CPQIDA-MIB |
| 1.3.6.1.4.1.232.3.2.5 | cpqDaPhyDrv | CPQIDA-MIB |
| 1.3.6.1.4.1.232.3.2.5.1 | cpqDaPhyDrvTable | CPQIDA-MIB |
| 1.3.6.1.4.1.232.3.2.5.1.1 | cpqDaPhyDrvEntry | CPQIDA-MIB |
| 1.3.6.1.4.1.232.3.2.5.1.1.26 | cpqDaPhyDrvDrqTimeouts | CPQIDA-MIB |