CPQIDA-MIB :: cpqDaPhyDrvDrqTimeouts

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsCPQIDA-MIBcpqDaPhyDrvDrqTimeouts

cpqDaPhyDrvDrqTimeouts

Module: CPQIDA-MIB

OID (symbolic): CPQIDA-MIB::cpqDaPhyDrvDrqTimeouts

OID (numeric): 1.3.6.1.4.1.232.3.2.5.1.1.26

Node type: OBJECT-TYPE

Type: Counter

Access: read-only

Description: DRQ Timeouts.

The number of times that a physical drive continued to request data, but did not get a command completion during the reference time (phyDrvRefTime). This value increases every time a DRQ timeout occurs for the physical drive.

A defective drive or cable may cause DRQ timeouts to occur. If you see an increase in these errors, complete the following steps for the monitored system:

1. Check the cables connecting the drive to ensure that they are intact.

2. If the cables are properly connected, schedule server down time to run diagnostics to verify that a problem exists.

If the value is not supported, it is set to 4,294,967,295.

What is cpqDaPhyDrvDrqTimeouts?

cpqDaPhyDrvDrqTimeouts counts how many times a physical drive kept requesting data (DRQ) but never returned command completion during the reference time window. A rising value points to a defective drive or a bad cable interrupting the data-request handshake between drive and controller. For example, an admin seeing this counter increase on one bay would first reseat or replace that drive's cable before assuming the drive itself has failed.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.232.3.2.5.1.1.26
snmpwalk -v2c -c public <target> CPQIDA-MIB::cpqDaPhyDrvDrqTimeouts

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.232.3.2.5.1.1.26.1
snmpget -v2c -c public <target> CPQIDA-MIB::cpqDaPhyDrvDrqTimeouts.1

Start monitoring Compaq/HP ProLiant server (Smart Array/Intelligent Drive Array RAID controller) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CPQIDA-MIB::cpqDaPhyDrvDrqTimeouts OID value, configure state conditions and alerts, and monitor any Compaq/HP ProLiant server (Smart Array/Intelligent Drive Array RAID controller) from a single console.

OID Breakdown

Upper-level ancestors (7 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.232compaqCOMPAQ-ID-REC-MIB
Numeric OIDNameModule
1.3.6.1.4.1.232.3cpqDriveArrayCPQIDA-MIB
1.3.6.1.4.1.232.3.2cpqDaComponentCPQIDA-MIB
1.3.6.1.4.1.232.3.2.5cpqDaPhyDrvCPQIDA-MIB
1.3.6.1.4.1.232.3.2.5.1cpqDaPhyDrvTableCPQIDA-MIB
1.3.6.1.4.1.232.3.2.5.1.1cpqDaPhyDrvEntryCPQIDA-MIB
1.3.6.1.4.1.232.3.2.5.1.1.26cpqDaPhyDrvDrqTimeoutsCPQIDA-MIB