CPQIDA-MIB :: cpqDaPhyDrvConfigurationStatus

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsCPQIDA-MIBcpqDaPhyDrvConfigurationStatus

cpqDaPhyDrvConfigurationStatus

Module: CPQIDA-MIB

OID (symbolic): CPQIDA-MIB::cpqDaPhyDrvConfigurationStatus

OID (numeric): 1.3.6.1.4.1.232.3.2.5.1.1.58

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-only

Description: Physical Drive Configuration Status.

The following values are defined:

other(1) The agent is unable to determine the configuration status of this physical drive.

configured(2) Indicates the drive is configured to be part of a logical drive as either a member drive or a spare drive.

notConfigured(3) Indicates the drive is not configured to be part of a logical drive as either a member drive or a spare drive.

What is cpqDaPhyDrvConfigurationStatus?

cpqDaPhyDrvConfigurationStatus reports whether a physical drive is configured, meaning it's part of a logical drive as a member or spare, or notConfigured, meaning it's not assigned to any logical drive. This tells an admin at a glance which physical drives in a chassis are actually protecting data versus sitting idle as spares or free bays. For example, an admin planning to add a new logical drive would look for drives reporting notConfigured as candidates to include.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.232.3.2.5.1.1.58
snmpwalk -v2c -c public <target> CPQIDA-MIB::cpqDaPhyDrvConfigurationStatus

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.232.3.2.5.1.1.58.1
snmpget -v2c -c public <target> CPQIDA-MIB::cpqDaPhyDrvConfigurationStatus.1

SNMPv3 example:

snmpget -v3 -l authPriv -u snmpv3-user -a SHA -A "AuthPassword1" -x AES -X "PrivPassword1" <target> cpqDaPhyDrvConfigurationStatus.1

Start monitoring Compaq/HP ProLiant server (Smart Array/Intelligent Drive Array RAID controller) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CPQIDA-MIB::cpqDaPhyDrvConfigurationStatus OID value, configure state conditions and alerts, and monitor any Compaq/HP ProLiant server (Smart Array/Intelligent Drive Array RAID controller) from a single console.

OID Breakdown

Upper-level ancestors (7 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.232compaqCOMPAQ-ID-REC-MIB
Numeric OIDNameModule
1.3.6.1.4.1.232.3cpqDriveArrayCPQIDA-MIB
1.3.6.1.4.1.232.3.2cpqDaComponentCPQIDA-MIB
1.3.6.1.4.1.232.3.2.5cpqDaPhyDrvCPQIDA-MIB
1.3.6.1.4.1.232.3.2.5.1cpqDaPhyDrvTableCPQIDA-MIB
1.3.6.1.4.1.232.3.2.5.1.1cpqDaPhyDrvEntryCPQIDA-MIB
1.3.6.1.4.1.232.3.2.5.1.1.58cpqDaPhyDrvConfigurationStatusCPQIDA-MIB