All MIBs › CPQIDA-MIB › cpqDaPhyDrvBlockValid
cpqDaPhyDrvBlockValid
Module: CPQIDA-MIB
OID (symbolic): CPQIDA-MIB::cpqDaPhyDrvBlockValid
OID (numeric): 1.3.6.1.4.1.232.3.2.5.2.1.11
Node type: OBJECT-TYPE
Type: INTEGER
Access: read-only
Description: Physical Drive Error Log Block Address Is Valid.
The valid values are:
False (1) Indicates that the Block Address object (cpqDaPhyDrvBlock) is not a valid address.
True (2) Indicates that the Block Address object (cpqDaPhyDrvBlock) is a valid address.
What is cpqDaPhyDrvBlockValid?
cpqDaPhyDrvBlockValid is a false/true flag indicating whether the block address reported in cpqDaPhyDrvBlock for an error log entry is actually a valid address. Because not every SCSI error includes a meaningful block address, this flag tells an admin whether they can trust that address to locate the exact failing sector on the drive. For example, if this flag reads false for a given error log entry, an admin would know not to rely on cpqDaPhyDrvBlock for that entry when trying to pinpoint the affected sector.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.232.3.2.5.2.1.11 snmpwalk -v2c -c public <target> CPQIDA-MIB::cpqDaPhyDrvBlockValid
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.232.3.2.5.2.1.11.1 snmpget -v2c -c public <target> CPQIDA-MIB::cpqDaPhyDrvBlockValid.1
Start monitoring Compaq/HP ProLiant server (Smart Array/Intelligent Drive Array RAID controller) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CPQIDA-MIB::cpqDaPhyDrvBlockValid OID value, configure state conditions and alerts, and monitor any Compaq/HP ProLiant server (Smart Array/Intelligent Drive Array RAID controller) from a single console.
OID Breakdown
Upper-level ancestors (7 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.232 | compaq | COMPAQ-ID-REC-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.232.3 | cpqDriveArray | CPQIDA-MIB |
| 1.3.6.1.4.1.232.3.2 | cpqDaComponent | CPQIDA-MIB |
| 1.3.6.1.4.1.232.3.2.5 | cpqDaPhyDrv | CPQIDA-MIB |
| 1.3.6.1.4.1.232.3.2.5.2 | cpqDaPhyDrvErrTable | CPQIDA-MIB |
| 1.3.6.1.4.1.232.3.2.5.2.1 | cpqDaPhyDrvErrEntry | CPQIDA-MIB |
| 1.3.6.1.4.1.232.3.2.5.2.1.11 | cpqDaPhyDrvBlockValid | CPQIDA-MIB |