CPQIDA-MIB :: cpqDaLogDrvRebuildingPhyDrv

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsCPQIDA-MIBcpqDaLogDrvRebuildingPhyDrv

cpqDaLogDrvRebuildingPhyDrv

Module: CPQIDA-MIB

OID (symbolic): CPQIDA-MIB::cpqDaLogDrvRebuildingPhyDrv

OID (numeric): 1.3.6.1.4.1.232.3.2.3.1.1.17

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-only

Description: Logical Drive Physical Drive Rebuilding Index.

This is the physical drive index of the physical drive that is currently rebuilding. If the value cannot be determined or is not applicable, the value is set to -1.

What is cpqDaLogDrvRebuildingPhyDrv?

This integer is the physical drive index of the drive currently rebuilding within this logical drive, returning -1 if not applicable or undetermined. An admin uses this to identify exactly which physical drive to avoid removing while a rebuild is actively in progress. For example, cpqDaLogDrvRebuildingPhyDrv reporting drive index 3 tells the admin that specific drive bay is mid-rebuild and shouldn't be disturbed.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.232.3.2.3.1.1.17
snmpwalk -v2c -c public <target> CPQIDA-MIB::cpqDaLogDrvRebuildingPhyDrv

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.232.3.2.3.1.1.17.1
snmpget -v2c -c public <target> CPQIDA-MIB::cpqDaLogDrvRebuildingPhyDrv.1

Start monitoring Compaq/HP ProLiant server (Smart Array/Intelligent Drive Array RAID controller) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CPQIDA-MIB::cpqDaLogDrvRebuildingPhyDrv OID value, configure state conditions and alerts, and monitor any Compaq/HP ProLiant server (Smart Array/Intelligent Drive Array RAID controller) from a single console.

OID Breakdown

Upper-level ancestors (7 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.232compaqCOMPAQ-ID-REC-MIB
Numeric OIDNameModule
1.3.6.1.4.1.232.3cpqDriveArrayCPQIDA-MIB
1.3.6.1.4.1.232.3.2cpqDaComponentCPQIDA-MIB
1.3.6.1.4.1.232.3.2.3cpqDaLogDrvCPQIDA-MIB
1.3.6.1.4.1.232.3.2.3.1cpqDaLogDrvTableCPQIDA-MIB
1.3.6.1.4.1.232.3.2.3.1.1cpqDaLogDrvEntryCPQIDA-MIB
1.3.6.1.4.1.232.3.2.3.1.1.17cpqDaLogDrvRebuildingPhyDrvCPQIDA-MIB