cpqDaLogDrvCacheVolAccelNoOfReadMissDoLoad

Module: CPQIDA-MIB

OID (symbolic): CPQIDA-MIB::cpqDaLogDrvCacheVolAccelNoOfReadMissDoLoad

OID (numeric): 1.3.6.1.4.1.232.3.2.3.5.1.9

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-only

Description: Drive Array Logical Drive Cache Volume Accelerator Number Of Read Cache Misses - Do Load (low).

cpqDaLogDrvCacheVolAccelNoOfReadMissDoLoad and cpqDaLogDrvCacheVolAccelNoOfReadMissDoLoadH together show the number of times a read cache request for this cache volume was missed and prompted a load of data from the primary storage to the drive cache. If the value cannot be determined or is not applicable, it is set to -1.

What is cpqDaLogDrvCacheVolAccelNoOfReadMissDoLoad?

This integer holds the low-order 32 bits of a 64-bit counter of read cache misses that triggered a data load from primary storage into the drive cache, paired with the high-order cpqDaLogDrvCacheVolAccelNoOfReadMissDoLoad H value, and returns -1 if not applicable. An admin watches this to see how often the accelerator has to fetch fresh data because it wasn't already cached, indicating cold-data access patterns. For example, a high cpqDaLogDrvCacheVolAccelNoOfReadMissDoLoad relative to read hits suggests the working set is larger than the cache can hold, so admins might consider adding more cache volume capacity.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.232.3.2.3.5.1.9
snmpwalk -v2c -c public <target> CPQIDA-MIB::cpqDaLogDrvCacheVolAccelNoOfReadMissDoLoad

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.232.3.2.3.5.1.9.1
snmpget -v2c -c public <target> CPQIDA-MIB::cpqDaLogDrvCacheVolAccelNoOfReadMissDoLoad.1

Start monitoring Compaq/HP ProLiant server (Smart Array/Intelligent Drive Array RAID controller) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CPQIDA-MIB::cpqDaLogDrvCacheVolAccelNoOfReadMissDoLoad OID value, configure state conditions and alerts, and monitor any Compaq/HP ProLiant server (Smart Array/Intelligent Drive Array RAID controller) from a single console.

OID Breakdown

Upper-level ancestors (7 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.232compaqCOMPAQ-ID-REC-MIB
Numeric OIDNameModule
1.3.6.1.4.1.232.3cpqDriveArrayCPQIDA-MIB
1.3.6.1.4.1.232.3.2cpqDaComponentCPQIDA-MIB
1.3.6.1.4.1.232.3.2.3cpqDaLogDrvCPQIDA-MIB
1.3.6.1.4.1.232.3.2.3.5cpqDaLogDrvCacheVolumeAccelTableCPQIDA-MIB
1.3.6.1.4.1.232.3.2.3.5.1cpqDaLogDrvCacheVolumeAccelEntryCPQIDA-MIB
1.3.6.1.4.1.232.3.2.3.5.1.9cpqDaLogDrvCacheVolAccelNoOfReadMissDoLoadCPQIDA-MIB