All MIBs › CPQIDA-MIB › cpqDaLogDrvCacheVolAccelAssocType
cpqDaLogDrvCacheVolAccelAssocType
Module: CPQIDA-MIB
OID (symbolic): CPQIDA-MIB::cpqDaLogDrvCacheVolAccelAssocType
OID (numeric): 1.3.6.1.4.1.232.3.2.3.1.1.21
Node type: OBJECT-TYPE
Type: INTEGER
Access: read-only
Description: Logical Drive Cache Volume Accelerator Association Type.
Indicates the way in which this logical drive is associated with a cache volume accelerator group.
The following values are defined:
Other(1) The instrument agent is unable to determine if this logical drive is part of a cache volume accelerator group. Logical drive cache volume acceleration may not be enabled on this controller or you may need to upgrade the instrument agent.
Non Member (2) Indicates that this logical drive is not a member of a cache volume accelerator group.
Logical Drive Member(3) This logical drive is using a cache volume.
Cache Volume Member(4) This logical drive is being utilized as a cache volume.
What is cpqDaLogDrvCacheVolAccelAssocType?
This enumerated value indicates how this logical drive is associated with a cache volume accelerator group, as nonMember, logicalDriveMember, or cacheVolumeMember. An admin checks this to understand whether a given logical drive row represents the actual data volume or the special cache-volume accelerator entry paired with it. For example, cpqDaLogDrvCacheVolAccelAssocType reporting cacheVolumeMember identifies that particular logical drive row as the SSD-based accelerator volume rather than the underlying production data volume.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.232.3.2.3.1.1.21 snmpwalk -v2c -c public <target> CPQIDA-MIB::cpqDaLogDrvCacheVolAccelAssocType
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.232.3.2.3.1.1.21.1 snmpget -v2c -c public <target> CPQIDA-MIB::cpqDaLogDrvCacheVolAccelAssocType.1
Start monitoring Compaq/HP ProLiant server (Smart Array/Intelligent Drive Array RAID controller) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CPQIDA-MIB::cpqDaLogDrvCacheVolAccelAssocType OID value, configure state conditions and alerts, and monitor any Compaq/HP ProLiant server (Smart Array/Intelligent Drive Array RAID controller) from a single console.
OID Breakdown
Upper-level ancestors (7 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.232 | compaq | COMPAQ-ID-REC-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.232.3 | cpqDriveArray | CPQIDA-MIB |
| 1.3.6.1.4.1.232.3.2 | cpqDaComponent | CPQIDA-MIB |
| 1.3.6.1.4.1.232.3.2.3 | cpqDaLogDrv | CPQIDA-MIB |
| 1.3.6.1.4.1.232.3.2.3.1 | cpqDaLogDrvTable | CPQIDA-MIB |
| 1.3.6.1.4.1.232.3.2.3.1.1 | cpqDaLogDrvEntry | CPQIDA-MIB |
| 1.3.6.1.4.1.232.3.2.3.1.1.21 | cpqDaLogDrvCacheVolAccelAssocType | CPQIDA-MIB |