CPQIDA-MIB :: cpqDaCntlrRedundancyError

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsCPQIDA-MIBcpqDaCntlrRedundancyError

cpqDaCntlrRedundancyError

Module: CPQIDA-MIB

OID (symbolic): CPQIDA-MIB::cpqDaCntlrRedundancyError

OID (numeric): 1.3.6.1.4.1.232.3.2.2.1.1.17

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-only

Description: Array Controller Redundancy Error.

The following values are valid:

other (1) Indicates that the instrument agent does not recognize the redundancy error of the controller. You may need to upgrade the instrument agent.

noFailure (2) No failures have been detected.

noRedundantController (3) No redundant controller is installed.

differentHardware (4) The other controller indicates a different hardware model.

noLink (5) An inter-controller link to the other controller could not be established.

differentFirmware (6) The other controller indicates a different firmware version.

differentCache (7) The other controller indicates a different cache size.

otherCacheFailure (8) The other controller indicates a cache failure.

noDrives (9) This controller cannot see any attached drives, but the other controller can.

otherNoDrives (10) This controller can see the attached drives, but the other controller cannot.

unsupportedDrives (11) One or more attached drives has been determined to be incapable of properly supporting redundant controller operation.

expandInProgress (12) Expand operation in progress. Redundant operation not supported until expand operation is complete.

What is cpqDaCntlrRedundancyError?

This enumerated value reports the specific reason redundancy is impaired for a duplexed controller pair, such as noRedundantController, differentHardware, noLink, or differentFirmware. An admin uses this to diagnose exactly why a redundant configuration isn't functioning as expected rather than just knowing that it isn't. For example, cpqDaCntlrRedundancyError reporting differentFirmware(6) tells the admin to update the partner controller's firmware to match before redundancy can be restored.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.232.3.2.2.1.1.17
snmpwalk -v2c -c public <target> CPQIDA-MIB::cpqDaCntlrRedundancyError

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.232.3.2.2.1.1.17.1
snmpget -v2c -c public <target> CPQIDA-MIB::cpqDaCntlrRedundancyError.1

Start monitoring Compaq/HP ProLiant server (Smart Array/Intelligent Drive Array RAID controller) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CPQIDA-MIB::cpqDaCntlrRedundancyError OID value, configure state conditions and alerts, and monitor any Compaq/HP ProLiant server (Smart Array/Intelligent Drive Array RAID controller) from a single console.

OID Breakdown

Upper-level ancestors (7 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.232compaqCOMPAQ-ID-REC-MIB
Numeric OIDNameModule
1.3.6.1.4.1.232.3cpqDriveArrayCPQIDA-MIB
1.3.6.1.4.1.232.3.2cpqDaComponentCPQIDA-MIB
1.3.6.1.4.1.232.3.2.2cpqDaCntlrCPQIDA-MIB
1.3.6.1.4.1.232.3.2.2.1cpqDaCntlrTableCPQIDA-MIB
1.3.6.1.4.1.232.3.2.2.1.1cpqDaCntlrEntryCPQIDA-MIB
1.3.6.1.4.1.232.3.2.2.1.1.17cpqDaCntlrRedundancyErrorCPQIDA-MIB