CPQIDA-MIB :: cpqDaCntlrModel

MIB Reference — IPNetwork Monitor

All MIBsCPQIDA-MIBcpqDaCntlrModel

cpqDaCntlrModel

Module: CPQIDA-MIB

OID (symbolic): CPQIDA-MIB::cpqDaCntlrModel

OID (numeric): 1.3.6.1.4.1.232.3.2.2.1.1.2

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-only

Description:

Array Controller Model.

The type of controller card. The valid types are:

Other (1) You may need to upgrade your driver software and\or instrument agent(s). You have a drive array controller in the system that the instrument agent does not recognize.

IDA (2) Compaq 32-Bit Intelligent Drive Array Controller. The physical drives are located inside the system.

IDA Expansion (3) Compaq 32-Bit Intelligent Drive Array Expansion Controller. The physical drives are located in the Array Expansion System that is connected to the system by a cable.

IDA - 2 (4) Compaq Intelligent Drive Array Controller-2 (IDA-2). The physical drives are located inside the system.

SMART (5) Compaq SMART Array Controller. The physical drives can be located inside the system or outside the system in a ProLiant Storage System that is connected to the system by a cable.

SMART - 2/E (6) Compaq SMART-2/E Array Controller. The physical drives can be located inside the system or outside the system in a ProLiant Storage System that is connected to the system by a cable.

SMART - 2/P (7) Compaq SMART-2/P Array Controller. The physical drives can be located inside the system or outside the system in a ProLiant Storage System that is connected to the system by a cable.

SMART - 2SL (8) Compaq SMART-2SL Array Controller. The physical drives can be located inside the system or outside the system in a ProLiant Storage System that is connected to the system by a cable.

Smart - 3100ES (9) Compaq Smart Array 3100ES Controller. The physical drives are located inside the system.

Smart - 3200 (10) Compaq Smart Array 3200 Controller. The physical drives can be located inside the system or outside the system in a ProLiant Storage System that is connected to the system by a cable.

SMART - 2DH (11) Compaq SMART-2DH Array Controller. The physical drives can be located inside the system or outside the system in a ProLiant Storage System that is connected to the system by a cable.

Smart - 221 (12) Compaq Smart Array 221 Controller. The physical drives can be located inside the system or outside the system in a ProLiant Storage System that is connected to the system by a cable.

Smart Array 4250ES (13) Compaq Smart Array 4250ES Controller. The physical drives are located inside the system.

Smart Array 4200 (14) Compaq Smart Array 4200 Controller. The physical drives can be located inside the system or outside the system in a ProLiant Storage System that is connected to the system by a cable.

Integrated Smart Array (15) Compaq Integrated Smart Array Controller. The physical drives can be located inside the system or outside the system in a ProLiant Storage System that is connected to the system by a cable.

Smart Array 431 (16) Compaq Smart Array 431 Controller. The physical drives can be located inside the system or outside the system in a ProLiant Storage System that is connected to the system by a cable.

Smart Array 5300 (17) HP Smart Array 5300 Controller.

RAID LC2 Controller (18) Compaq RAID LC2 Controller.

Smart Array 5i (19) HP Smart Array 5i Controller.

Smart Array 532 (20) Compaq Smart Array 532 Controller.

Smart Array 5312 (21) Compaq Smart Array 5312 Controller.

Smart Array 641 (22) HP Smart Array 641 Controller.

Smart Array 642 (23) HP Smart Array 642 Controller.

Smart Array 6400 (24) HP Smart Array 6400 Controller.

Smart Array 6400 EM (25) HP Smart Array 6400 EM Controller.

Smart Array 6i (26) HP Smart Array 6i Controller.

Generic Array (27) Array Controller.

Reserved (28)

Smart Array P600 (29) HP Smart Array P600 Controller.

Smart Array P400 (30) HP Smart Array P400 Controller.

Smart Array E200 (31) HP Smart Array E200 Controller.

Smart Array E200i (32) HP Smart Array E200i Controller.

Smart Array P400i (33) HP Smart Array P400i Controller.

Smart Array P800 (34) HP Smart Array P800 Controller.

Smart Array E500 (35) HP Smart Array E500 Controller.

Smart Array P700m (36) HP Smart Array P700m Controller.

Smart Array P212 (37) HP Smart Array P212 Controller.

Smart Array P410 (38) HP Smart Array P410 Controller.

Smart Array P410i (39) HP Smart Array P410i Controller.

Smart Array P411 (40) HP Smart Array P411 Controller.

Smart Array B110i SATA RAID (41) HP Smart Array B110i SATA RAID Controller.

Smart Array P712m (42) HP Smart Array P712m Controller.

Smart Array P711m (43) HP Smart Array P711m Controller.

Smart Array P812 (44) HP Smart Array P812 Controller.

StorageWorks 1210m (45) HP StorageWorks 1210m Scalable Storage Controller.

Smart Array P220i (46) HP Smart Array P220i Controller.

Smart Array P222 (47) HP Smart Array P222 Controller.

Smart Array P420 (48) HP Smart Array P420 Controller.

Smart Array P420i (49) HP Smart Array P420i Controller.

Smart Array P421 (50) HP Smart Array P421 Controller.

Smart Array B320i (51) HP Dynamic Smart Array B320i Controller.

Smart Array P822 (52) HP Smart Array P822 Controller.

Smart Array P721m (53) HP Smart Array P721m Controller.

Smart Array B120i (54) HP Dynamic Smart Array B120i Controller.

HP Storage p1224 (55) HP Storage p1224 Array Controller.

HP Storage p1228 (56) HP Storage p1228 Array Controller.

HP Storage p1228m (57) HP Storage p1228m Array Controller.

Smart Array P822se (58) HP Smart Array P822se Controller.

HP Storage p1224e (59) HP Storage p1224e Array Controller.

HP Storage p1228e (60) HP Storage p1228e Array Controller.

HP Storage p1228em (61) HP Storage p1228em Array Controller.

Smart Array P230i (62) HP Smart Array P230i Controller.

Smart Array P430i (63) HP Smart Array P430i Controller.

Smart Array P430 (64) HP Smart Array P430 Controller.

Smart Array P431 (65) HP Smart Array P431 Controller.

Smart Array P731m (66) HP Smart Array P731m Controller.

Smart Array P830i (67) HP Smart Array P830i Controller.

Smart Array P830 (68) HP Smart Array P830 Controller.

Smart Array P831 (69) HP Smart Array P831 Controller.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.232.3.2.2.1.1.2
snmpwalk -v2c -c public <target> CPQIDA-MIB::cpqDaCntlrModel

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.232.3.2.2.1.1.2.1
snmpget -v2c -c public <target> CPQIDA-MIB::cpqDaCntlrModel.1

OID Breakdown

Numeric OIDNameModule
1isoLANART-AGENT
1.3orgBIANCA-BRICK-PPP-MIB
1.3.6dodBIANCA-BRICK-PPP-MIB
1.3.6.1internetBIANCA-BRICK-PPP-MIB
1.3.6.1.4privateBIANCA-BRICK-PPP-MIB
1.3.6.1.4.1enterprisesANIROOT-MIB
1.3.6.1.4.1.232compaqCOMPAQ-ID-REC-MIB
1.3.6.1.4.1.232.3cpqDriveArrayCPQIDA-MIB
1.3.6.1.4.1.232.3.2cpqDaComponentCPQIDA-MIB
1.3.6.1.4.1.232.3.2.2cpqDaCntlrCPQIDA-MIB
1.3.6.1.4.1.232.3.2.2.1cpqDaCntlrTableCPQIDA-MIB
1.3.6.1.4.1.232.3.2.2.1.1cpqDaCntlrEntryCPQIDA-MIB
1.3.6.1.4.1.232.3.2.2.1.1.2cpqDaCntlrModelCPQIDA-MIB