All MIBs › CPQHSV110V3-MIB › sCellEventTrap10
sCellEventTrap10
Module: CPQHSV110V3-MIB
OID (symbolic): CPQHSV110V3-MIB::sCellEventTrap10
OID (numeric): 1.3.6.1.4.1.232.0.13600256
Node type: NOTIFICATION-TYPE
Description: Severity: Normal -- informational in nature. During Executive Services initialization the system time value was set to the value contained in the time field. The action field contains one of the following codes which describes the condition that caused the time value to be chosen:
- 0 = TOY clock unavailable; time reset to default date and time.
- 1 = TOY clock time value was less than or equal to the last known time value previously stored in nonvolatile memory; time reset to default date and time.
- 2 = EDC was bad for last known time value previously stored in nonvolatile memory; time reset to default date and time.
- 3 = TOY clock not running; time reset to default date and time.
- 4 = TOY clock time value believed to be accurate; time set to TOY clock time value.
Examples
Send this trap to an SNMP manager — replace <manager> with the IP or hostname of your monitoring server (SNMPv2c):
snmptrap -v2c -c public <manager> '' CPQHSV110V3-MIB::sCellEventTrap10 snmptrap -v2c -c public <manager> '' 1.3.6.1.4.1.232.0.13600256
Listen for incoming traps on the manager host (-f keeps it in the foreground, -Lo prints to stdout — useful for testing):
snmptrapd -f -Lo -c /dev/null authCommunity log public
Example snmptrapd log entry:
zoo11-linux.zoo [UDP: [192.168.30.111]:61312->[192.168.30.10]:162]: DISMAN-EVENT-MIB::sysUpTimeInstance = Timeticks: (24547200) 2 days, 20:11:12.00 SNMPv2-MIB::snmpTrapOID.0 = OID: CPQHSV110V3-MIB::sCellEventTrap10
SNMPv3 example:
snmptrap -v3 -l authPriv -u snmpv3user -a SHA -A "AuthPass1" -x AES -X "PrivPass1" <manager> '' CPQHSV110V3-MIB::sCellEventTrap10
Start monitoring HP StorageWorks HSV110 (EVA) array controller with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CPQHSV110V3-MIB::sCellEventTrap10 OID value, configure state conditions and alerts, and monitor any HP StorageWorks HSV110 (EVA) array controller from a single console.
OID Breakdown
Upper-level ancestors (7 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.232 | compaq | COMPAQ-ID-REC-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.232.0.13600256 | sCellEventTrap10 | CPQHSV110V3-MIB |