All MIBs › CPQHSV-MIB › sCellEventTrap_0d_4c
sCellEventTrap_0d_4c
Module: CPQHSV-MIB
OID (symbolic): CPQHSV-MIB::sCellEventTrap_0d_4c
OID (numeric): 1.3.6.1.4.1.232.0.13603404
Node type: NOTIFICATION-TYPE
Description: Severity: Critical -- failure or failure imminent. Both drive enclosure blowers are missing. This severely affects the drive enclosure air flow and can cause an over temperature condition. The operational power supply(s) will automatically shut down after a short period of time, thereby disabling the drive enclosure. This condition remains active until either the problem is corrected, or the operational power supply(s) shut down, whichever occurs first.
Examples
Send this trap to an SNMP manager — replace <manager> with the IP or hostname of your monitoring server (SNMPv2c):
snmptrap -v2c -c public <manager> '' CPQHSV-MIB::sCellEventTrap_0d_4c snmptrap -v2c -c public <manager> '' 1.3.6.1.4.1.232.0.13603404
Listen for incoming traps on the manager host (-f keeps it in the foreground, -Lo prints to stdout — useful for testing):
snmptrapd -f -Lo -c /dev/null authCommunity log public
Example snmptrapd log entry:
zoo11-linux.zoo [UDP: [192.168.30.111]:59829->[192.168.30.10]:162]: DISMAN-EVENT-MIB::sysUpTimeInstance = Timeticks: (86802869) 10 days, 1:07:08.69 SNMPv2-MIB::snmpTrapOID.0 = OID: CPQHSV-MIB::sCellEventTrap_0d_4c
Start monitoring HP/Compaq StorageWorks HSV SAN array controller (EVA) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CPQHSV-MIB::sCellEventTrap_0d_4c OID value, configure state conditions and alerts, and monitor any HP/Compaq StorageWorks HSV SAN array controller (EVA) from a single console.
OID Breakdown
Upper-level ancestors (7 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.232 | compaq | COMPAQ-ID-REC-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.232.0.13603404 | sCellEventTrap_0d_4c | CPQHSV-MIB |