CPQHLTH-MIB :: cpqHeThermalSystemFanFailed

MIB Reference — IPNetwork Monitor

All MIBsCPQHLTH-MIBcpqHeThermalSystemFanFailed

cpqHeThermalSystemFanFailed

Module: CPQHLTH-MIB

OID (symbolic): CPQHLTH-MIB::cpqHeThermalSystemFanFailed

OID (numeric): 1.3.6.1.4.1.232.0.6006

Node type: NOTIFICATION-TYPE

Description:

The system fan status has been set to failed. A required system fan is not operating normally. The system will be shutdown if the cpqHeThermalDegradedAction variable is set to shutdown(3).

Examples

Send this trap to an SNMP manager — replace <manager> with the IP or hostname of your monitoring server (SNMPv2c):

snmptrap -v2c -c public <manager> '' CPQHLTH-MIB::cpqHeThermalSystemFanFailed
snmptrap -v2c -c public <manager> '' 1.3.6.1.4.1.232.0.6006

Listen for incoming traps on the manager host (-f keeps it in the foreground, -Lo prints to stdout — useful for testing):

snmptrapd -f -Lo -c /dev/null authCommunity log public

Example snmptrapd log entry:

zoo11-linux.zoo [UDP: [192.168.30.111]:53048->[192.168.30.10]:162]:
  DISMAN-EVENT-MIB::sysUpTimeInstance = Timeticks: (240641336) 27 days, 20:26:53.36
  SNMPv2-MIB::snmpTrapOID.0 = OID: CPQHLTH-MIB::cpqHeThermalSystemFanFailed

OID Breakdown

Numeric OIDNameModule
1isoLANART-AGENT
1.3orgBIANCA-BRICK-PPP-MIB
1.3.6dodBIANCA-BRICK-PPP-MIB
1.3.6.1internetBIANCA-BRICK-PPP-MIB
1.3.6.1.4privateBIANCA-BRICK-PPP-MIB
1.3.6.1.4.1enterprisesANIROOT-MIB
1.3.6.1.4.1.232compaqCOMPAQ-ID-REC-MIB
1.3.6.1.4.1.232.0.6006cpqHeThermalSystemFanFailedCPQHLTH-MIB