All MIBs › CPQHLTH-MIB › cpqHeThermalFanCpuFan
cpqHeThermalFanCpuFan
Module: CPQHLTH-MIB
OID (symbolic): CPQHLTH-MIB::cpqHeThermalFanCpuFan
OID (numeric): 1.3.6.1.4.1.232.6.2.6.6.1.4
Node type: OBJECT-TYPE
Type: INTEGER
Access: read-only
Description: This specifies if the described fan is intended specifically to cool the CPU(s).
What is cpqHeThermalFanCpuFan?
This read-only enumerated value (other, systemFan, cpuFan) classifies whether this particular fan cools the CPU specifically or the general system. An admin uses this to know which failed-fan alert maps to the stricter CPU-fan handling versus the more lenient system-fan handling. A fan flagged cpuFan failing is treated more urgently than one flagged systemFan, per the corresponding status objects.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.232.6.2.6.6.1.4 snmpwalk -v2c -c public <target> CPQHLTH-MIB::cpqHeThermalFanCpuFan
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.232.6.2.6.6.1.4.1 snmpget -v2c -c public <target> CPQHLTH-MIB::cpqHeThermalFanCpuFan.1
Start monitoring HP/Compaq ProLiant server (hardware health MIB) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CPQHLTH-MIB::cpqHeThermalFanCpuFan OID value, configure state conditions and alerts, and monitor any HP/Compaq ProLiant server (hardware health MIB) from a single console.
OID Breakdown
Upper-level ancestors (7 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.232 | compaq | COMPAQ-ID-REC-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.232.6 | cpqHealth | CPQHLTH-MIB |
| 1.3.6.1.4.1.232.6.2 | cpqHeComponent | CPQHLTH-MIB |
| 1.3.6.1.4.1.232.6.2.6 | cpqHeThermal | CPQHLTH-MIB |
| 1.3.6.1.4.1.232.6.2.6.6 | cpqHeThermalFanTable | CPQHLTH-MIB |
| 1.3.6.1.4.1.232.6.2.6.6.1 | cpqHeThermalFanEntry | CPQHLTH-MIB |
| 1.3.6.1.4.1.232.6.2.6.6.1.4 | cpqHeThermalFanCpuFan | CPQHLTH-MIB |