All MIBs › CPQHLTH-MIB › cpqHe3PowerConverterDegraded
cpqHe3PowerConverterDegraded
Module: CPQHLTH-MIB
OID (symbolic): CPQHLTH-MIB::cpqHe3PowerConverterDegraded
OID (numeric): 1.3.6.1.4.1.232.0.6043
Node type: NOTIFICATION-TYPE
Description:
The DC-DC Power Converter condition has been set to degraded for the specified chassis, slot and socket.
Examples
Send this trap to an SNMP manager — replace <manager> with the IP or hostname of your monitoring server (SNMPv2c):
snmptrap -v2c -c public <manager> '' CPQHLTH-MIB::cpqHe3PowerConverterDegraded snmptrap -v2c -c public <manager> '' 1.3.6.1.4.1.232.0.6043
Listen for incoming traps on the manager host (-f keeps it in the foreground, -Lo prints to stdout — useful for testing):
snmptrapd -f -Lo -c /dev/null authCommunity log public
Example snmptrapd log entry:
zoo11-linux.zoo [UDP: [192.168.30.111]:65203->[192.168.30.10]:162]: DISMAN-EVENT-MIB::sysUpTimeInstance = Timeticks: (441849011) 51 days, 3:21:30.11 SNMPv2-MIB::snmpTrapOID.0 = OID: CPQHLTH-MIB::cpqHe3PowerConverterDegraded
OID Breakdown
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | BIANCA-BRICK-PPP-MIB |
| 1.3.6 | dod | BIANCA-BRICK-PPP-MIB |
| 1.3.6.1 | internet | BIANCA-BRICK-PPP-MIB |
| 1.3.6.1.4 | private | BIANCA-BRICK-PPP-MIB |
| 1.3.6.1.4.1 | enterprises | ANIROOT-MIB |
| 1.3.6.1.4.1.232 | compaq | COMPAQ-ID-REC-MIB |
| 1.3.6.1.4.1.232.0.6043 | cpqHe3PowerConverterDegraded | CPQHLTH-MIB |