CPQFCA-MIB :: cpqFcaPhyDrvSpinupTime

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsCPQFCA-MIBcpqFcaPhyDrvSpinupTime

cpqFcaPhyDrvSpinupTime

Module: CPQFCA-MIB

OID (symbolic): CPQFCA-MIB::cpqFcaPhyDrvSpinupTime

OID (numeric): 1.3.6.1.4.1.232.16.2.5.1.1.21

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-only

Description: Spin up Time in tenths of seconds.

This is the time it takes for a physical drive to spin up to full speed.

Disks require time to gain momentum and reach operating speed. As cars are tested to go from 0 mph to 60 mph in x number of seconds, drive manufacturers have preset expectations for the time it takes the drive to spin to full speed. Drives that do not meet these expectations may have problems.

The value may be zero (0) under one of the following conditions:

* If you are monitoring a physical drive that is part of the monitored system's internal drive array storage, and you use a warm boot to reset the monitored system. During a warm boot, the drives continue to spin.

* If you are monitoring a physical drive in an ProLiant Storage System storage and you reset the array but not the ProLiant Storage System.

If the value cannot be determined, -1 is returned.

What is cpqFcaPhyDrvSpinupTime?

This integer reports, in tenths of a second, how long the physical drive took to spin up to full operating speed. An admin compares this against the drive manufacturer's expected spin-up time, since drives that take noticeably longer than expected to reach speed may be developing mechanical problems. For example, a spin-up time far exceeding the drive's rated specification, even though the drive is still reporting ok status, would be worth flagging for closer monitoring.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.232.16.2.5.1.1.21
snmpwalk -v2c -c public <target> CPQFCA-MIB::cpqFcaPhyDrvSpinupTime

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.232.16.2.5.1.1.21.1
snmpget -v2c -c public <target> CPQFCA-MIB::cpqFcaPhyDrvSpinupTime.1

Start monitoring Legacy Compaq Fibre Channel Array (CPQFCA) storage controller with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CPQFCA-MIB::cpqFcaPhyDrvSpinupTime OID value, configure state conditions and alerts, and monitor any Legacy Compaq Fibre Channel Array (CPQFCA) storage controller from a single console.

OID Breakdown

Upper-level ancestors (7 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.232compaqCOMPAQ-ID-REC-MIB
Numeric OIDNameModule
1.3.6.1.4.1.232.16cpqFibreArrayCPQFCA-MIB
1.3.6.1.4.1.232.16.2cpqFcaComponentCPQFCA-MIB
1.3.6.1.4.1.232.16.2.5cpqFcaPhyDrvCPQFCA-MIB
1.3.6.1.4.1.232.16.2.5.1cpqFcaPhyDrvTableCPQFCA-MIB
1.3.6.1.4.1.232.16.2.5.1.1cpqFcaPhyDrvEntryCPQFCA-MIB
1.3.6.1.4.1.232.16.2.5.1.1.21cpqFcaPhyDrvSpinupTimeCPQFCA-MIB