CPQFCA-MIB :: cpqFcaPhyDrvRecvReadErrs

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsCPQFCA-MIBcpqFcaPhyDrvRecvReadErrs

cpqFcaPhyDrvRecvReadErrs

Module: CPQFCA-MIB

OID (symbolic): CPQFCA-MIB::cpqFcaPhyDrvRecvReadErrs

OID (numeric): 1.3.6.1.4.1.232.16.2.5.1.1.16

Node type: OBJECT-TYPE

Type: Counter

Access: read-only

Description: Recovered Read Errors.

This shows the number of read errors corrected through physical drive retries during the reference time (phyDrvRefTime).

Over time, all disk drives produce these errors. If you notice a rapid increase in the value for Recovered Read Errors (or Hard Read Errors), a problem may exist with the drive. The value increases every time the physical drive detects and corrects another error.

Expect more Recovered Read Errors than Hard Read Errors. If you suspect that a problem may exist with the drive, run diagnostics.

If the value cannot be determined, 4,294,967,295 is returned.

What is cpqFcaPhyDrvRecvReadErrs?

This counter reports the number of read errors that were successfully corrected through the physical drive's own retry mechanism during the reference time. An admin monitors this because although occasional recovered errors are normal for any disk, a rapid increase in this value alongside hard read errors suggests the drive is beginning to fail. For example, a recovered read error count climbing sharply week over week on one specific drive would flag it as a replacement candidate before it produces uncorrectable errors.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.232.16.2.5.1.1.16
snmpwalk -v2c -c public <target> CPQFCA-MIB::cpqFcaPhyDrvRecvReadErrs

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.232.16.2.5.1.1.16.1
snmpget -v2c -c public <target> CPQFCA-MIB::cpqFcaPhyDrvRecvReadErrs.1

Start monitoring Legacy Compaq Fibre Channel Array (CPQFCA) storage controller with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CPQFCA-MIB::cpqFcaPhyDrvRecvReadErrs OID value, configure state conditions and alerts, and monitor any Legacy Compaq Fibre Channel Array (CPQFCA) storage controller from a single console.

OID Breakdown

Upper-level ancestors (7 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.232compaqCOMPAQ-ID-REC-MIB
Numeric OIDNameModule
1.3.6.1.4.1.232.16cpqFibreArrayCPQFCA-MIB
1.3.6.1.4.1.232.16.2cpqFcaComponentCPQFCA-MIB
1.3.6.1.4.1.232.16.2.5cpqFcaPhyDrvCPQFCA-MIB
1.3.6.1.4.1.232.16.2.5.1cpqFcaPhyDrvTableCPQFCA-MIB
1.3.6.1.4.1.232.16.2.5.1.1cpqFcaPhyDrvEntryCPQFCA-MIB
1.3.6.1.4.1.232.16.2.5.1.1.16cpqFcaPhyDrvRecvReadErrsCPQFCA-MIB