All MIBs › CPQFCA-MIB › cpqFcaPhyDrvPreFailMonitoring
cpqFcaPhyDrvPreFailMonitoring
Module: CPQFCA-MIB
OID (symbolic): CPQFCA-MIB::cpqFcaPhyDrvPreFailMonitoring
OID (numeric): 1.3.6.1.4.1.232.16.2.5.1.1.44
Node type: OBJECT-TYPE
Type: INTEGER
Access: read-only
Description: Physical Drive Predictive Failure Monitoring.
The following values are defined:
other(1) The agent is unable to determine if the drive supports predictive failure monitoring.
notAvailable(2) This drive does not support predictive failure monitoring.
available(3) This drive supports predictive failure monitoring.
What is cpqFcaPhyDrvPreFailMonitoring?
This enumerated value indicates whether the physical drive supports predictive failure monitoring, as other, notAvailable, or available. An admin checks this to know whether a given drive can provide advance warning (via cpqFcaPhyDrvStatus's predictiveFailure state) before it actually fails, or whether it will only ever report an abrupt failed status. For example, notAvailable(2) on an older drive model means the admin cannot rely on early warning for that disk and should plan more frequent manual health checks.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.232.16.2.5.1.1.44 snmpwalk -v2c -c public <target> CPQFCA-MIB::cpqFcaPhyDrvPreFailMonitoring
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.232.16.2.5.1.1.44.1 snmpget -v2c -c public <target> CPQFCA-MIB::cpqFcaPhyDrvPreFailMonitoring.1
Start monitoring Legacy Compaq Fibre Channel Array (CPQFCA) storage controller with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CPQFCA-MIB::cpqFcaPhyDrvPreFailMonitoring OID value, configure state conditions and alerts, and monitor any Legacy Compaq Fibre Channel Array (CPQFCA) storage controller from a single console.
OID Breakdown
Upper-level ancestors (7 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.232 | compaq | COMPAQ-ID-REC-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.232.16 | cpqFibreArray | CPQFCA-MIB |
| 1.3.6.1.4.1.232.16.2 | cpqFcaComponent | CPQFCA-MIB |
| 1.3.6.1.4.1.232.16.2.5 | cpqFcaPhyDrv | CPQFCA-MIB |
| 1.3.6.1.4.1.232.16.2.5.1 | cpqFcaPhyDrvTable | CPQFCA-MIB |
| 1.3.6.1.4.1.232.16.2.5.1.1 | cpqFcaPhyDrvEntry | CPQFCA-MIB |
| 1.3.6.1.4.1.232.16.2.5.1.1.44 | cpqFcaPhyDrvPreFailMonitoring | CPQFCA-MIB |