cpqFcaPhyDrvNotReadyErrs

Module: CPQFCA-MIB

OID (symbolic): CPQFCA-MIB::cpqFcaPhyDrvNotReadyErrs

OID (numeric): 1.3.6.1.4.1.232.16.2.5.1.1.29

Node type: OBJECT-TYPE

Type: Counter

Access: read-only

Description: Drive Not Ready Errors.

The number of times the physical drive failed after the spin up command was issued during the reference time (phyDrvRefTime). When the spin up command was issued, the drive failed to reach its ready state. If the current value is zero, the drive has not failed. If the current value is greater than zero, at least one failure occurred.

This error could be caused because the physical drive has failed to spin.

If you suspect a problem:

1. Check the cables connecting the drive to ensure that they are intact.

2. If the cables are properly connected, run diagnostics to verify that a problem exists.

If the value cannot be determined, 4,294,967,295 is returned.

What is cpqFcaPhyDrvNotReadyErrs?

This counter reports the number of times the physical drive failed to reach its ready state after a spin-up command was issued, during the reference time, with zero meaning the drive has never failed to spin up. An admin treats any nonzero value as a sign the drive is having trouble becoming operational and should be tested. For example, a drive showing repeated not-ready errors after routine power cycles would be a strong candidate for replacement even if it currently reports an ok status.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.232.16.2.5.1.1.29
snmpwalk -v2c -c public <target> CPQFCA-MIB::cpqFcaPhyDrvNotReadyErrs

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.232.16.2.5.1.1.29.1
snmpget -v2c -c public <target> CPQFCA-MIB::cpqFcaPhyDrvNotReadyErrs.1

Start monitoring Legacy Compaq Fibre Channel Array (CPQFCA) storage controller with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CPQFCA-MIB::cpqFcaPhyDrvNotReadyErrs OID value, configure state conditions and alerts, and monitor any Legacy Compaq Fibre Channel Array (CPQFCA) storage controller from a single console.

OID Breakdown

Upper-level ancestors (7 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.232compaqCOMPAQ-ID-REC-MIB
Numeric OIDNameModule
1.3.6.1.4.1.232.16cpqFibreArrayCPQFCA-MIB
1.3.6.1.4.1.232.16.2cpqFcaComponentCPQFCA-MIB
1.3.6.1.4.1.232.16.2.5cpqFcaPhyDrvCPQFCA-MIB
1.3.6.1.4.1.232.16.2.5.1cpqFcaPhyDrvTableCPQFCA-MIB
1.3.6.1.4.1.232.16.2.5.1.1cpqFcaPhyDrvEntryCPQFCA-MIB
1.3.6.1.4.1.232.16.2.5.1.1.29cpqFcaPhyDrvNotReadyErrsCPQFCA-MIB