cpqFcaLogDrvBlinkTime

Module: CPQFCA-MIB

OID (symbolic): CPQFCA-MIB::cpqFcaLogDrvBlinkTime

OID (numeric): 1.3.6.1.4.1.232.16.2.3.1.1.14

Node type: OBJECT-TYPE

Type: Counter

Access: read-write

Description: External Array Logical Drive Physical Drive Blink Time Count.

The logical drive blink time variable allows the drive tray LEDs of all physical drives in a logical drive to blink. This value indicates the amount of time, in tenths of a second, that the physical drive LEDs will continue to blink. A value of zero indicates the drive LEDs are not blinking. If the value cannot be determined or no drive in this logical drive is in a hot plug tray, 4,294,967,295 is returned.

To blink the drive LEDs on all physical drives in this logical drive (including any configured spare drives), set this value to the time to blink in tenths of seconds.

To stop the drive LEDs from blinking, set this value to 0.

What is cpqFcaLogDrvBlinkTime?

This read-write counter controls how long, in tenths of a second, the drive tray LEDs of all physical drives in this logical drive continue to blink, with zero meaning the LEDs are not blinking. An admin sets this remotely to make a specific logical drive's physical bays flash so a technician standing at the storage box can visually identify which drives to service. For example, writing a value of 3000 makes the drives blink for five minutes, enough time to walk to the server room and locate the right bays.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.232.16.2.3.1.1.14
snmpwalk -v2c -c public <target> CPQFCA-MIB::cpqFcaLogDrvBlinkTime

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.232.16.2.3.1.1.14.1
snmpget -v2c -c public <target> CPQFCA-MIB::cpqFcaLogDrvBlinkTime.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.232.16.2.3.1.1.14.1 i <value>

Start monitoring Legacy Compaq Fibre Channel Array (CPQFCA) storage controller with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CPQFCA-MIB::cpqFcaLogDrvBlinkTime OID value, configure state conditions and alerts, and monitor any Legacy Compaq Fibre Channel Array (CPQFCA) storage controller from a single console.

OID Breakdown

Upper-level ancestors (7 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.232compaqCOMPAQ-ID-REC-MIB
Numeric OIDNameModule
1.3.6.1.4.1.232.16cpqFibreArrayCPQFCA-MIB
1.3.6.1.4.1.232.16.2cpqFcaComponentCPQFCA-MIB
1.3.6.1.4.1.232.16.2.3cpqFcaLogDrvCPQFCA-MIB
1.3.6.1.4.1.232.16.2.3.1cpqFcaLogDrvTableCPQFCA-MIB
1.3.6.1.4.1.232.16.2.3.1.1cpqFcaLogDrvEntryCPQFCA-MIB
1.3.6.1.4.1.232.16.2.3.1.1.14cpqFcaLogDrvBlinkTimeCPQFCA-MIB