CPQFCA-MIB :: cpqFcaAccelBadData

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsCPQFCA-MIBcpqFcaAccelBadData

cpqFcaAccelBadData

Module: CPQFCA-MIB

OID (symbolic): CPQFCA-MIB::cpqFcaAccelBadData

OID (numeric): 1.3.6.1.4.1.232.16.2.2.2.1.4

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-only

Description: Array Accelerator Board Bad Data.

The following values are valid:

None (2) Indicates that no data loss occurred. The battery packs were properly charged when the system was initialized.

Possible (3) Indicates that at power up, the battery packs were not sufficiently charged. Because the batteries did not retain sufficient charge when the system resumed power, the board has not retained any data that may have been stored. If no data was on the board, no data was lost. Several things may have caused this condition:

* If the system was without power for eight days, and the battery packs were on (battery packs only activate if system looses power unexpectedly), any data that may have been stored in the cache was lost.

* There may be a problem with the battery pack. See the Battery Status for more information.

* This status will also appear if the Array Accelerator board is replaced with a new board that has discharged batteries. No data has been lost in this case, and posted writes will automatically be enabled when the batteries reach full charge.

What is cpqFcaAccelBadData?

This read-only enumerated value reports whether the Fibre Channel array accelerator board experienced possible data loss: none(2) meaning the battery packs were properly charged at initialization, or possible(3) meaning the batteries were insufficiently charged at power-up so cached data may not have been retained. An administrator treats a possible(3) reading as a serious data-integrity warning requiring investigation before trusting recently written data. Seeing possible(3) after an unexpected power event would prompt an admin to verify the affected logical drives for potential data corruption before returning them to production.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.232.16.2.2.2.1.4
snmpwalk -v2c -c public <target> CPQFCA-MIB::cpqFcaAccelBadData

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.232.16.2.2.2.1.4.1
snmpget -v2c -c public <target> CPQFCA-MIB::cpqFcaAccelBadData.1

Start monitoring Legacy Compaq Fibre Channel Array (CPQFCA) storage controller with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CPQFCA-MIB::cpqFcaAccelBadData OID value, configure state conditions and alerts, and monitor any Legacy Compaq Fibre Channel Array (CPQFCA) storage controller from a single console.

OID Breakdown

Upper-level ancestors (7 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.232compaqCOMPAQ-ID-REC-MIB
Numeric OIDNameModule
1.3.6.1.4.1.232.16cpqFibreArrayCPQFCA-MIB
1.3.6.1.4.1.232.16.2cpqFcaComponentCPQFCA-MIB
1.3.6.1.4.1.232.16.2.2cpqFcaCntlrCPQFCA-MIB
1.3.6.1.4.1.232.16.2.2.2cpqFcaAccelTableCPQFCA-MIB
1.3.6.1.4.1.232.16.2.2.2.1cpqFcaAccelEntryCPQFCA-MIB
1.3.6.1.4.1.232.16.2.2.2.1.4cpqFcaAccelBadDataCPQFCA-MIB