CPQFCA-MIB :: cpqFcTapeLibraryRedundancy

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsCPQFCA-MIBcpqFcTapeLibraryRedundancy

cpqFcTapeLibraryRedundancy

Module: CPQFCA-MIB

OID (symbolic): CPQFCA-MIB::cpqFcTapeLibraryRedundancy

OID (numeric): 1.3.6.1.4.1.232.16.3.2.1.1.18

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-only

Description: External Tape Library Redundancy Status.

Redundancy status denotes the presence of internal redundant components such as fans, power supplies, etc. The library redundancy can be in one of the following states:

other(1) The library redundancy status is unknown.

notSupported(2) Indicates that the library cannot detect or report redundancy status.

capable(3) Indicates that the library is capable of detecting and reporting redundant components but there are not enough redundant units installed to make redundancy active.

notCapable(4) Indicates that the library is capable of detecting and reporting redundant components but there are no components that support redundancy.

active(5) Indicates that the library is capable of detecting and reporting redundant components, there are enough redundant units installed, and redundancy is active.

What is cpqFcTapeLibraryRedundancy?

This enumerated value reports the redundancy status of internal components such as fans and power supplies in the tape library, as other, notSupported, capable, notCapable, or active. An admin checks this to know whether the library can tolerate a single internal component failure without an outage. For example, notCapable(4) tells the admin this particular library has no redundant internal power or cooling, making any single component failure a potential full outage.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.232.16.3.2.1.1.18
snmpwalk -v2c -c public <target> CPQFCA-MIB::cpqFcTapeLibraryRedundancy

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.232.16.3.2.1.1.18.1
snmpget -v2c -c public <target> CPQFCA-MIB::cpqFcTapeLibraryRedundancy.1

Start monitoring Legacy Compaq Fibre Channel Array (CPQFCA) storage controller with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CPQFCA-MIB::cpqFcTapeLibraryRedundancy OID value, configure state conditions and alerts, and monitor any Legacy Compaq Fibre Channel Array (CPQFCA) storage controller from a single console.

OID Breakdown

Upper-level ancestors (7 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.232compaqCOMPAQ-ID-REC-MIB
Numeric OIDNameModule
1.3.6.1.4.1.232.16cpqFibreArrayCPQFCA-MIB
1.3.6.1.4.1.232.16.3cpqFcTapeComponentCPQFCA-MIB
1.3.6.1.4.1.232.16.3.2cpqFcTapeLibraryCPQFCA-MIB
1.3.6.1.4.1.232.16.3.2.1cpqFcTapeLibraryTableCPQFCA-MIB
1.3.6.1.4.1.232.16.3.2.1.1cpqFcTapeLibraryEntryCPQFCA-MIB
1.3.6.1.4.1.232.16.3.2.1.1.18cpqFcTapeLibraryRedundancyCPQFCA-MIB