All MIBs › CM-ALARM-MIB › f3EnvAlarmInputCondType
f3EnvAlarmInputCondType
Module: CM-ALARM-MIB
OID (symbolic): CM-ALARM-MIB::f3EnvAlarmInputCondType
OID (numeric): 1.3.6.1.4.1.2544.1.12.6.1.7.1.3
Node type: OBJECT-TYPE
Type: CmConditionType
Access: read-write
Description: This object allows SNMP management entities to provide the environmental alarm condition associated with the environmental alarm input.
What is f3EnvAlarmInputCondType?
This read-write CmConditionType lets management assign the alarm condition type associated with an environmental alarm input. An admin cares because it classifies what kind of fault a given physical input's trigger should be reported as, consistent with other condition types elsewhere in the system. For example, an admin configures one input's condition type as a door-open condition so its trigger is classified consistently with other door-open events.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.2544.1.12.6.1.7.1.3 snmpwalk -v2c -c public <target> CM-ALARM-MIB::f3EnvAlarmInputCondType
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.2544.1.12.6.1.7.1.3.1 snmpget -v2c -c public <target> CM-ALARM-MIB::f3EnvAlarmInputCondType.1
Set instance 1 (SNMPv2c):
snmpset -v2c -c private <target> 1.3.6.1.4.1.2544.1.12.6.1.7.1.3.1 s <value>
Start monitoring ADVA/Ceragon FSP150 CM/CC (F3) microwave & Carrier Ethernet transport platform with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CM-ALARM-MIB::f3EnvAlarmInputCondType OID value, configure state conditions and alerts, and monitor any ADVA/Ceragon FSP150 CM/CC (F3) microwave & Carrier Ethernet transport platform from a single console.
OID Breakdown
Upper-level ancestors (9 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.2544 | advaMIB | ADVA-MIB |
| 1.3.6.1.4.1.2544.1 | products | ADVA-MIB |
| 1.3.6.1.4.1.2544.1.12 | fsp150cm | ADVA-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.2544.1.12.6 | cmAlarmMIB | CM-ALARM-MIB |
| 1.3.6.1.4.1.2544.1.12.6.1 | alarmObjects | CM-ALARM-MIB |
| 1.3.6.1.4.1.2544.1.12.6.1.7 | f3EnvAlarmInputTable | CM-ALARM-MIB |
| 1.3.6.1.4.1.2544.1.12.6.1.7.1 | f3EnvAlarmInputEntry | CM-ALARM-MIB |
| 1.3.6.1.4.1.2544.1.12.6.1.7.1.3 | f3EnvAlarmInputCondType | CM-ALARM-MIB |