All MIBs › CISCOSB-Physicaldescription-MIB › rlPhdPoePresent
rlPhdPoePresent
Module: CISCOSB-Physicaldescription-MIB
OID (symbolic): CISCOSB-Physicaldescription-MIB::rlPhdPoePresent
OID (numeric): 1.3.6.1.4.1.9.6.1.101.53.20.1.2
Node type: OBJECT-TYPE
Type: INTEGER
Access: read-only
Description: The present state of the PoE module. The no(1) state indicates that the PoE module is not present. The yes{2) state indicates that the PoE module is present.
What is rlPhdPoePresent?
This read-only INTEGER reports whether a PoE power module is physically present, yes, or absent, no, on the associated stack unit. An admin troubleshooting why PoE devices on a particular unit are not powering up should check this first, since a missing PoE module makes any PoE-related configuration on that unit's ports moot. For example, if an IP phone plugged into a port on unit 2 will not power on and this field reports no for that unit, the admin knows the unit itself lacks a PoE module rather than there being a port-configuration problem.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.9.6.1.101.53.20.1.2 snmpwalk -v2c -c public <target> CISCOSB-Physicaldescription-MIB::rlPhdPoePresent
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.9.6.1.101.53.20.1.2.1 snmpget -v2c -c public <target> CISCOSB-Physicaldescription-MIB::rlPhdPoePresent.1
Start monitoring Cisco Small Business stackable switches with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CISCOSB-Physicaldescription-MIB::rlPhdPoePresent OID value, configure state conditions and alerts, and monitor any Cisco Small Business stackable switches from a single console.
OID Breakdown
Upper-level ancestors (11 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.9 | cisco | CAT2600-MIB |
| 1.3.6.1.4.1.9.6 | otherEnterprises | CISCO-SMI |
| 1.3.6.1.4.1.9.6.1 | ciscoSB | CISCO-SMI |
| 1.3.6.1.4.1.9.6.1.101 | switch001 | CISCOSB-MIB |
| 1.3.6.1.4.1.9.6.1.101.53 | rlPhysicalDescription | CISCOSB-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.9.6.1.101.53.20 | rlPhdPoeTable | CISCOSB-Physicaldescription-MIB |
| 1.3.6.1.4.1.9.6.1.101.53.20.1 | rlPhdPoeEntry | CISCOSB-Physicaldescription-MIB |
| 1.3.6.1.4.1.9.6.1.101.53.20.1.2 | rlPhdPoePresent | CISCOSB-Physicaldescription-MIB |