CISCO-WAN-SVC-MIB :: cwspSscopIgnoredPduRcv

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsCISCO-WAN-SVC-MIBcwspSscopIgnoredPduRcv

cwspSscopIgnoredPduRcv

Module: CISCO-WAN-SVC-MIB

OID (symbolic): CISCO-WAN-SVC-MIB::cwspSscopIgnoredPduRcv

OID (numeric): 1.3.6.1.4.1.351.140.1.2.7.1.1.2

Node type: OBJECT-TYPE

Type: Counter32

Access: read-only

Description: This object stores the number of SSCOP PDUs that are received but ignored due to incorrect size, invalid PDU, unknown PDU type.

What is cwspSscopIgnoredPduRcv?

This read-only counter tracks the number of SSCOP PDUs received on this interface that were ignored due to incorrect size, an invalid PDU, or an unknown PDU type. It gives an admin a direct signal of malformed or unrecognized signaling traffic arriving on this link, which often points to a version mismatch or link corruption. For example, a sudden rise in this counter after connecting to a new peer switch could indicate an SSCOP protocol incompatibility.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.351.140.1.2.7.1.1.2
snmpwalk -v2c -c public <target> CISCO-WAN-SVC-MIB::cwspSscopIgnoredPduRcv

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.351.140.1.2.7.1.1.2.1
snmpget -v2c -c public <target> CISCO-WAN-SVC-MIB::cwspSscopIgnoredPduRcv.1

Start monitoring Cisco BPX-SES/MGX ATM switch (legacy) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CISCO-WAN-SVC-MIB::cwspSscopIgnoredPduRcv OID value, configure state conditions and alerts, and monitor any Cisco BPX-SES/MGX ATM switch (legacy) from a single console.

How to Use in IPNetwork Monitor

Select a Cisco BPX-SES/MGX ATM switch (legacy) as the target host to create a monitor — the SNMP service should be up and running on it. Click New Monitor, then check SNMP Custom on the Favorites tab, click Next, and confirm the host. On the next page, click Select... to open the built-in SNMP MIB Browser and type cwspSscopIgnoredPduRcv into the Find box to locate it in the OID tree, selecting the specific row/instance you want to monitor since this is a table column, then select it and click OK. This object stores the number of SSCOP PDUs that are received but ignored due to incorrect size, invalid PDU, unknown PDU type. On the monitor's Main parameters page you can set the target's SNMP port (default 161), credentials, polling interval, and other settings — see the SNMP Monitor help for details. On the State conditions and Alerting tabs, configure when the monitor should change state and trigger an alert; since this is a Counter32-type OID, Value bounds is the most useful condition here — trigger an alert if the counter increases between polls, since a rising count of errors, failures, or discards often points to a real underlying problem. Click Finish to create the monitor; you can adjust any parameter later.

OID Breakdown

Upper-level ancestors (7 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.351stratacomCISCOWAN-SMI
Numeric OIDNameModule
1.3.6.1.4.1.351.140ciscoWANSvcMIBCISCO-WAN-SVC-MIB
1.3.6.1.4.1.351.140.1ciscoWANSvcMIBObjectsCISCO-WAN-SVC-MIB
1.3.6.1.4.1.351.140.1.2ciscoWANSvcPortCISCO-WAN-SVC-MIB
1.3.6.1.4.1.351.140.1.2.7cwspSscopStatsCISCO-WAN-SVC-MIB
1.3.6.1.4.1.351.140.1.2.7.1cwspSscopStatsTableCISCO-WAN-SVC-MIB
1.3.6.1.4.1.351.140.1.2.7.1.1cwspSscopStatsEntryCISCO-WAN-SVC-MIB
1.3.6.1.4.1.351.140.1.2.7.1.1.2cwspSscopIgnoredPduRcvCISCO-WAN-SVC-MIB