CISCO-WAN-SVC-MIB :: cwspAbrCallFwdAdtf

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsCISCO-WAN-SVC-MIBcwspAbrCallFwdAdtf

cwspAbrCallFwdAdtf

Module: CISCO-WAN-SVC-MIB

OID (symbolic): CISCO-WAN-SVC-MIB::cwspAbrCallFwdAdtf

OID (numeric): 1.3.6.1.4.1.351.140.1.2.9.1.1.27

Node type: OBJECT-TYPE

Type: Integer32

Access: read-only

Description: The Allowed Cell Rate (ACR) Decrease Time Factor for the ABR call in the forward direction. This is the time permitted between sending RM-cells before the rate is decreased to ICR. Range is 10 ms to 10.23 seconds. The unit is 10 msecs. For example, the default value of 50 corresponds to a time factor of 500 ms. Larger values allow a source to retain its current rate longer, during periods of relative inactivity. The default is 50 (0.5 seconds).

What is cwspAbrCallFwdAdtf?

This read-only Integer32 (1..1023), in units of 10 milliseconds, reports the Allowed Cell Rate (ACR) Decrease Time Factor for the ABR call in the forward direction, the time permitted between RM-cells before the rate is decreased to ICR, with the default value of 50 corresponding to 500ms. An administrator uses this to understand how long this specific ABR call can go idle before its allowed rate is automatically dropped back down to the conservative Initial Cell Rate. For example, a source on this call that pauses for longer than cwspAbrCallFwdAdtf's configured time (500ms at the default of 50) has its rate reset to cwspAbrCallFwdIcr and must ramp back up from there on resumption.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.351.140.1.2.9.1.1.27
snmpwalk -v2c -c public <target> CISCO-WAN-SVC-MIB::cwspAbrCallFwdAdtf

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.351.140.1.2.9.1.1.27.1
snmpget -v2c -c public <target> CISCO-WAN-SVC-MIB::cwspAbrCallFwdAdtf.1

Start monitoring Cisco BPX-SES/MGX ATM switch (legacy) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CISCO-WAN-SVC-MIB::cwspAbrCallFwdAdtf OID value, configure state conditions and alerts, and monitor any Cisco BPX-SES/MGX ATM switch (legacy) from a single console.

OID Breakdown

Upper-level ancestors (7 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.351stratacomCISCOWAN-SMI
Numeric OIDNameModule
1.3.6.1.4.1.351.140ciscoWANSvcMIBCISCO-WAN-SVC-MIB
1.3.6.1.4.1.351.140.1ciscoWANSvcMIBObjectsCISCO-WAN-SVC-MIB
1.3.6.1.4.1.351.140.1.2ciscoWANSvcPortCISCO-WAN-SVC-MIB
1.3.6.1.4.1.351.140.1.2.9cwspAbrCallCISCO-WAN-SVC-MIB
1.3.6.1.4.1.351.140.1.2.9.1cwspAbrCallTableCISCO-WAN-SVC-MIB
1.3.6.1.4.1.351.140.1.2.9.1.1cwspAbrCallEntryCISCO-WAN-SVC-MIB
1.3.6.1.4.1.351.140.1.2.9.1.1.27cwspAbrCallFwdAdtfCISCO-WAN-SVC-MIB