CISCO-WAN-SONET-MIB :: cwsSectionStatisticalAlarmSeverity

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsCISCO-WAN-SONET-MIBcwsSectionStatisticalAlarmSeverity

cwsSectionStatisticalAlarmSeverity

Module: CISCO-WAN-SONET-MIB

OID (symbolic): CISCO-WAN-SONET-MIB::cwsSectionStatisticalAlarmSeverity

OID (numeric): 1.3.6.1.4.1.351.150.3.1.1.1.1.1

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-write

Description: By setting this object to major or minor, a minor or major severity alarm is raised when any statistical threshold is exceeded. By default TCA crossing does not raise any alarm.

What is cwsSectionStatisticalAlarmSeverity?

This object sets the alarm severity, major or minor, raised when a statistical threshold is exceeded on the SONET section layer, with the MIB noting that by default a threshold crossing alarm (TCA) does not raise any alarm at all. An administrator must explicitly configure this to major or minor if they want threshold crossings on section-layer error counters to generate a visible alarm rather than being silently recorded. For example, leaving this at its default of none would mean that even if the errored-seconds threshold is repeatedly exceeded on the section layer, no alarm would be raised to alert the administrator.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.351.150.3.1.1.1.1.1
snmpwalk -v2c -c public <target> CISCO-WAN-SONET-MIB::cwsSectionStatisticalAlarmSeverity

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.351.150.3.1.1.1.1.1.1
snmpget -v2c -c public <target> CISCO-WAN-SONET-MIB::cwsSectionStatisticalAlarmSeverity.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.351.150.3.1.1.1.1.1.1 i <value>

Start monitoring Cisco WAN MGX-series SONET/SDH optical switch/multiplexer (legacy) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CISCO-WAN-SONET-MIB::cwsSectionStatisticalAlarmSeverity OID value, configure state conditions and alerts, and monitor any Cisco WAN MGX-series SONET/SDH optical switch/multiplexer (legacy) from a single console.

OID Breakdown

Upper-level ancestors (8 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.351stratacomCISCOWAN-SMI
1.3.6.1.4.1.351.150ciscoWanCISCOWAN-SMI
Numeric OIDNameModule
1.3.6.1.4.1.351.150.3ciscoWANSonetMIBCISCO-WAN-SONET-MIB
1.3.6.1.4.1.351.150.3.1ciscoWANSonetMIBObjectsCISCO-WAN-SONET-MIB
1.3.6.1.4.1.351.150.3.1.1cwsSectionCISCO-WAN-SONET-MIB
1.3.6.1.4.1.351.150.3.1.1.1cwsSectionAlarmTableCISCO-WAN-SONET-MIB
1.3.6.1.4.1.351.150.3.1.1.1.1cwsSectionAlarmEntryCISCO-WAN-SONET-MIB
1.3.6.1.4.1.351.150.3.1.1.1.1.1cwsSectionStatisticalAlarmSeverityCISCO-WAN-SONET-MIB