All MIBs › CISCO-UNIFIED-COMPUTING-VM-MIB › cucsVmVsanDn
cucsVmVsanDn
Module: CISCO-UNIFIED-COMPUTING-VM-MIB
OID (symbolic): CISCO-UNIFIED-COMPUTING-VM-MIB::cucsVmVsanDn
OID (numeric): 1.3.6.1.4.1.9.9.719.1.52.15.1.2
Node type: OBJECT-TYPE
Type: CucsManagedObjectDn
Access: read-only
Description: Cisco UCS vm:Vsan:dn managed object property
What is cucsVmVsanDn?
This read-only CucsManagedObjectDn value is the Distinguished Name (DN) of a VM-FEX VSAN object — the full hierarchical path UCS Manager uses to uniquely address one specific VM-FEX VSAN instance in its management-information tree. Since a UCS domain can contain many VM-FEX VSAN instances (one row per VSAN ID per fabric side known to the VM-FEX layer), the DN is what lets monitoring tools or scripts pin an SNMP row to the exact instance it describes rather than just the object type. For example, an admin troubleshooting a VM-FEX VSAN entry for VSAN 20 carrying FCoE traffic for a set of VM-hosted virtual HBAs would read this OID to get a DN like 'org-root/...dn', letting them jump straight to that instance in UCS Manager instead of searching through the whole tree.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.52.15.1.2 snmpwalk -v2c -c public <target> CISCO-UNIFIED-COMPUTING-VM-MIB::cucsVmVsanDn
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.52.15.1.2.1 snmpget -v2c -c public <target> CISCO-UNIFIED-COMPUTING-VM-MIB::cucsVmVsanDn.1
Start monitoring Cisco UCS (Unified Computing System) platforms (VM) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CISCO-UNIFIED-COMPUTING-VM-MIB::cucsVmVsanDn OID value, configure state conditions and alerts, and monitor any Cisco UCS (Unified Computing System) platforms (VM) from a single console.
OID Breakdown
Upper-level ancestors (10 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.9 | cisco | CAT2600-MIB |
| 1.3.6.1.4.1.9.9 | ciscoMgmt | CISCO-SMI |
| 1.3.6.1.4.1.9.9.719 | ciscoUnifiedComputingMIB | CISCO-UNIFIED-COMPUTING-MIB |
| 1.3.6.1.4.1.9.9.719.1 | ciscoUnifiedComputingMIBObjects | CISCO-UNIFIED-COMPUTING-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.9.9.719.1.52 | cucsVmObjects | CISCO-UNIFIED-COMPUTING-VM-MIB |
| 1.3.6.1.4.1.9.9.719.1.52.15 | cucsVmVsanTable | CISCO-UNIFIED-COMPUTING-VM-MIB |
| 1.3.6.1.4.1.9.9.719.1.52.15.1 | cucsVmVsanEntry | CISCO-UNIFIED-COMPUTING-VM-MIB |
| 1.3.6.1.4.1.9.9.719.1.52.15.1.2 | cucsVmVsanDn | CISCO-UNIFIED-COMPUTING-VM-MIB |