CISCO-UNIFIED-COMPUTING-TRIG-MIB :: cucsTrigTestDn

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsCISCO-UNIFIED-COMPUTING-TRIG-MIBcucsTrigTestDn

cucsTrigTestDn

Module: CISCO-UNIFIED-COMPUTING-TRIG-MIB

OID (symbolic): CISCO-UNIFIED-COMPUTING-TRIG-MIB::cucsTrigTestDn

OID (numeric): 1.3.6.1.4.1.9.9.719.1.50.5.1.2

Node type: OBJECT-TYPE

Type: CucsManagedObjectDn

Access: read-only

Description: Cisco UCS trig:Test:dn managed object property

What is cucsTrigTestDn?

This is the Distinguished Name (DN), a read-only string that gives the full hierarchical path UCS Manager uses to uniquely address a one-time test trigger created to validate a schedule's behavior on demand, without waiting for its normal recurrence. An administrator or monitoring tool reads this DN to know precisely which instance of the object a set of SNMP values belongs to, which matters because UCS Manager can have many sibling instances of the same class in its management tree. For example, when an administrator wants to verify a new maintenance schedule actually fires correctly before relying on it, this DN is what lets a script correlate the SNMP data back to the exact object shown in the UCS Manager GUI or CLI.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.50.5.1.2
snmpwalk -v2c -c public <target> CISCO-UNIFIED-COMPUTING-TRIG-MIB::cucsTrigTestDn

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.50.5.1.2.1
snmpget -v2c -c public <target> CISCO-UNIFIED-COMPUTING-TRIG-MIB::cucsTrigTestDn.1

Start monitoring Cisco UCS servers with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CISCO-UNIFIED-COMPUTING-TRIG-MIB::cucsTrigTestDn OID value, configure state conditions and alerts, and monitor any Cisco UCS servers from a single console.

OID Breakdown

Upper-level ancestors (10 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.9ciscoCAT2600-MIB
1.3.6.1.4.1.9.9ciscoMgmtCISCO-SMI
1.3.6.1.4.1.9.9.719ciscoUnifiedComputingMIBCISCO-UNIFIED-COMPUTING-MIB
1.3.6.1.4.1.9.9.719.1ciscoUnifiedComputingMIBObjectsCISCO-UNIFIED-COMPUTING-MIB
Numeric OIDNameModule
1.3.6.1.4.1.9.9.719.1.50cucsTrigObjectsCISCO-UNIFIED-COMPUTING-TRIG-MIB
1.3.6.1.4.1.9.9.719.1.50.5cucsTrigTestTableCISCO-UNIFIED-COMPUTING-TRIG-MIB
1.3.6.1.4.1.9.9.719.1.50.5.1cucsTrigTestEntryCISCO-UNIFIED-COMPUTING-TRIG-MIB
1.3.6.1.4.1.9.9.719.1.50.5.1.2cucsTrigTestDnCISCO-UNIFIED-COMPUTING-TRIG-MIB