All MIBs › CISCO-UNIFIED-COMPUTING-NFS-MIB › cucsNfsMountInstLocalDir
cucsNfsMountInstLocalDir
Module: CISCO-UNIFIED-COMPUTING-NFS-MIB
OID (symbolic): CISCO-UNIFIED-COMPUTING-NFS-MIB::cucsNfsMountInstLocalDir
OID (numeric): 1.3.6.1.4.1.9.9.719.1.67.6.1.17
Node type: OBJECT-TYPE
Type: SnmpAdminString
Access: read-only
Description: Cisco UCS nfs:MountInst:localDir managed object property
What is cucsNfsMountInstLocalDir?
On a MountInst object -- an NFS mount that UCS Manager has set up (for example a remote share used for backup images, firmware, or ISO repositories) -- cucsNfsMountInstLocalDir is a text (SnmpAdminString) field holding the local directory path on the UCS system where the remote NFS share is mounted. An admin reads this string because it carries the actual identifying detail -- not just an internal numeric ID -- needed to make sense of that specific MountInst instance. For example, an admin reviewing MountInst entries would look at cucsNfsMountInstLocalDir to see the concrete value rather than a bare object reference.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.67.6.1.17 snmpwalk -v2c -c public <target> CISCO-UNIFIED-COMPUTING-NFS-MIB::cucsNfsMountInstLocalDir
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.67.6.1.17.1 snmpget -v2c -c public <target> CISCO-UNIFIED-COMPUTING-NFS-MIB::cucsNfsMountInstLocalDir.1
Start monitoring Cisco UCS Manager-managed blade/rack servers and fabric interconnects with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CISCO-UNIFIED-COMPUTING-NFS-MIB::cucsNfsMountInstLocalDir OID value, configure state conditions and alerts, and monitor any Cisco UCS Manager-managed blade/rack servers and fabric interconnects from a single console.
OID Breakdown
Upper-level ancestors (10 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.9 | cisco | CAT2600-MIB |
| 1.3.6.1.4.1.9.9 | ciscoMgmt | CISCO-SMI |
| 1.3.6.1.4.1.9.9.719 | ciscoUnifiedComputingMIB | CISCO-UNIFIED-COMPUTING-MIB |
| 1.3.6.1.4.1.9.9.719.1 | ciscoUnifiedComputingMIBObjects | CISCO-UNIFIED-COMPUTING-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.9.9.719.1.67 | cucsNfsObjects | CISCO-UNIFIED-COMPUTING-NFS-MIB |
| 1.3.6.1.4.1.9.9.719.1.67.6 | cucsNfsMountInstTable | CISCO-UNIFIED-COMPUTING-NFS-MIB |
| 1.3.6.1.4.1.9.9.719.1.67.6.1 | cucsNfsMountInstEntry | CISCO-UNIFIED-COMPUTING-NFS-MIB |
| 1.3.6.1.4.1.9.9.719.1.67.6.1.17 | cucsNfsMountInstLocalDir | CISCO-UNIFIED-COMPUTING-NFS-MIB |