All MIBs › CISCO-UNIFIED-COMPUTING-NFS-MIB › cucsNfsMountDefFsmStageRn
cucsNfsMountDefFsmStageRn
Module: CISCO-UNIFIED-COMPUTING-NFS-MIB
OID (symbolic): CISCO-UNIFIED-COMPUTING-NFS-MIB::cucsNfsMountDefFsmStageRn
OID (numeric): 1.3.6.1.4.1.9.9.719.1.67.4.1.3
Node type: OBJECT-TYPE
Type: SnmpAdminString
Access: read-only
Description: Cisco UCS nfs:MountDefFsmStage:rn managed object property
What is cucsNfsMountDefFsmStageRn?
This OID carries the Relative Name (RN) of a MountDefFsmStage object, one individual step inside the MountDefFsm workflow that establishing an NFS mount passes through — the naming component that distinguishes this instance from its siblings under the same parent object. Because MountDefFsmStage instances are addressed by concatenating RNs down the management tree, an admin uses this value together with the parent DN to reconstruct exactly where this instance sits. For example, two MountDefFsmStage instances that share the same parent will report different cucsNfsMountDefFsmStageRn strings, letting a script tell them apart even when their other property values look identical.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.67.4.1.3 snmpwalk -v2c -c public <target> CISCO-UNIFIED-COMPUTING-NFS-MIB::cucsNfsMountDefFsmStageRn
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.67.4.1.3.1 snmpget -v2c -c public <target> CISCO-UNIFIED-COMPUTING-NFS-MIB::cucsNfsMountDefFsmStageRn.1
Start monitoring Cisco UCS Manager-managed blade/rack servers and fabric interconnects with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CISCO-UNIFIED-COMPUTING-NFS-MIB::cucsNfsMountDefFsmStageRn OID value, configure state conditions and alerts, and monitor any Cisco UCS Manager-managed blade/rack servers and fabric interconnects from a single console.
OID Breakdown
Upper-level ancestors (10 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.9 | cisco | CAT2600-MIB |
| 1.3.6.1.4.1.9.9 | ciscoMgmt | CISCO-SMI |
| 1.3.6.1.4.1.9.9.719 | ciscoUnifiedComputingMIB | CISCO-UNIFIED-COMPUTING-MIB |
| 1.3.6.1.4.1.9.9.719.1 | ciscoUnifiedComputingMIBObjects | CISCO-UNIFIED-COMPUTING-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.9.9.719.1.67 | cucsNfsObjects | CISCO-UNIFIED-COMPUTING-NFS-MIB |
| 1.3.6.1.4.1.9.9.719.1.67.4 | cucsNfsMountDefFsmStageTable | CISCO-UNIFIED-COMPUTING-NFS-MIB |
| 1.3.6.1.4.1.9.9.719.1.67.4.1 | cucsNfsMountDefFsmStageEntry | CISCO-UNIFIED-COMPUTING-NFS-MIB |
| 1.3.6.1.4.1.9.9.719.1.67.4.1.3 | cucsNfsMountDefFsmStageRn | CISCO-UNIFIED-COMPUTING-NFS-MIB |